Page 35
10. Diagnostics
The system state is communicated via two LED signal lamps on
the control device:
•
Operating display
•
Fault indication display
Fig. 12: LED signalling lamps on control device
10.1 System state
LED state
Significance
Possible cause
Troubleshooting
Green LED
flashes slowly
Idling
System is in stand-by mode
no demand for permeate
-
permanently lit
Operational
Permeate is produced
Solenoid valve in raw water pipe is
open
High-pressure pump is operational
-