background image

 

 
FAST & FLUID MANAGEMENT Australia Pty Ltd

 ABN 83 074 886 712

 

Box 1066 Unanderra NSW 2526 Australia  
T: +61 (0)2 4271 7111   F: +61 (0)2 4271 730

http://asia.fast-fluid.com

 

 

 

 

 

Technical Note

 

 

This is a guide to help prepare the X-Series Dispensers (X-SMART / X-PROTINT) to normal operation after a 
prolonged period of non-use. 
 
Before trying to dispense colorant, please follow the steps below: 
 

Tools 

 

Paper towel / cloth / wet wipes for cleaning and/or to remove dried colorants 

 

Anti mould spray if appropriate 

 

Gloves and/or any other personal protective equipment recommended by site, employer, etc.  

 
Procedure 

1.

 

Press E-Stop button on the dispenser  

2.

 

Check if the brush is clean, and that there is correct amount of cleaning liquid (water / solvent) in the 
brush container  

3.

 

Visually check the pump nozzles one by one. Wipe with a wet cloth / paper towel to ensure the 
nozzles are clean 

4.

 

Open the canister lid one by one and check the colorant condition. If colorant is hardened, thickened 
or mould has grown, take appropriate actions. You may need to contact the colorant supplier / paint 
supplier for further instructions 

5.

 

If dispenser is not connected to the power, connect to the power supply 

6.

 

Release the E-Stop button on the dispenser 

7.

 

Start up the PC if not yet done 

8.

 

Start up the dispenser software (e.g. PrismaPro). This should initialise the dispenser, and turn table 
should turn one or two times 

9.

 

After the initialization, the dispenser will automatically start agitation. If not, start agitation from the 
dispenser software (NOTE: for X-PROTIN, the front door needs to be closed to for agitation to initiate. 
Once agitation starts, then you can open the top cover to check if the stirrers are turning)   

10.

 

While dispenser is agitating, open the canister lid one by one and check if the stirrer blades are 
turning.  

a.

 

If none of the stirrer is turning, the agitation did not start successfully. You may need to 
consult with your service contact 

b.

 

If some stirrers are turning but others are not, stirrer may be damaged, or some other issues 
exist. You may be able to replace the stirrer if readily available or take other actions. You 
may need to consult with your service contact.  

11.

 

From the dispenser software, go to the fill canister option, and check each canister to ensure 
sufficient amount of colorant is in the canister, and that the software reflects the correct amount 

 

Date: 

Tuesday, 9 June 2020 

Applicable Equipment: 

X-Series Dispensers (X-SMART / X-PROTINT Dispenser) 

Subject: 

Start-up process following a prolonged idle period 

Отзывы: