3 | Product and technical specifications
HYDAC FILTER SYSTEMS GMBH
36 / 120
BeWa CTU1x5x 4603539 en-us web
3.5.1 Model Code
The model code is created according to the following model code.
Type
Size (height x width x depth)
Series
CTU 1 0 5 0 - M - Z - Z / -
Supplementary details
Extraction method
Modification
CTU = ContaminationTest Unit
1
0
2
Series
external flushing ports Ø 6 mm, between the manual interventions
Add flushing
Version
Test liquid
K
M
N
O
P
Z
U
5
Supply voltage
=
=
=
=
=
120 V AC / 60 Hz / single phase
230 V AC / 50 Hz / single phase
240 V AC / 50 Hz / single phase
240 V AC / 50 Hz / single phase
100 V AC / 50 Hz / single phase
USA / Canada
Europe
UK
Australia
Japan
Version 2020
=
Solvent cleaner (flash point≥ 60°C,
lower explosion limit>0.6 vol%)
Water with surfactants, permissible ph values 6 ... 10,
no fully demineralized water
or
solvent cleaner (flash point ≥ 60°C,
lower explosion limit >0.6 vol%)
0
1
=
=
1000 series
Extraction chamber dimensions 300 x 800 x 400 mm
Extraction chamber dimensions 550 x 800 x 650 mm
=
=
=
=
=
spraying, medium pressure
spraying, medium pressure with ultrasonic
Z
R
A
=
=
=
-
EA
=
=
without
extraction air (air extraction)
Fig. 5:
Model code
1
2
3
4
5
6
7
8
9
A