2 | Safety
HYDAC FILTER SYSTEMS GMBH
22 / 120
BeWa CTU1x5x 4603539 en-us web
Dangers with solvent cleaner as test liquid
WARNING
Static loading of components
Discharge / Explosion
u
Only use hoses/pipes with suitable conductivity.
u
Earth the test item if it is on a support that has an insulating ef-
fect.
u
Only use original spare parts.
CAUTION
Electrostatic charging of the door in the event of solvent cleaner as
test liquid
Danger of uncontrolled electrostatic discharge and ignition of a
gas-air mixture.
u
Clean the door with a moist, lint-free cloth and commonly avail-
able antistatic materials.
CAUTION
Solvent cleaner as test liquid
Health hazard
u
Follow all the instructions when handling the test liquid. Details
on this can be found in the safety data sheet of the test liquid.
u
Wear your personal protective equipment. Details on this can
be found in the safety data sheet of the test liquid.
u
Make sure that there is adequate air flow in the room. Details
on this can be found in the safety data sheet of the test liquid.
CAUTION
Solvent cleaner as test liquid
Danger to health by spraying test liquid or aerosols.
u
Ensure a closed extraction chamber during operation.
1
2
3
4
5
6
7
8
9
A