MERCHANDISER SETTINGS (Cont'd)
September 1, 1997
P/N 401789
7 - 11
HUSSM ANN CORPORATION • BRIDGETON, M O 63044-2483 • Printed in USA
Models
Refrigeration
Discharge Air
Temperature ÞF
Evaporator
TemperatureÞF
Fan Cycling
CI/CO ÞF
Defrost
Frequency, Hrs
Electric
Temp TermÞF
Failsafe Min
Reverse Air
Temp TermÞF
Failsafe Min
Koolgas
Duration Min
Offtime
Temp TermÞF
Duration Min
C2LE
C2E
C2LGE
27ÞF
21ÞF
—
6 Hrs
—
—
—
48ÞF
30 Min
C2XLE
C2XE
C2XLGE
29ÞF
21ÞF
—
6 Hrs
—
—
—
48ÞF
30 Min
D5L
D5
D6L
D6
D5LR
D5R
D5HR
31ÞF
21ÞF
—
6 Hrs
—
—
—
48ÞF
30 Min
D5LE
D5E
D5HE
D6LE
D6E
D5LRE
D5RE
D5HRE
D5NLE
D5NE
32ÞF
24ÞF
—
6 Hrs
—
—
—
48ÞF
35 Min
D5G
D5H
31ÞF
21ÞF
—
6 Hrs
—
—
—
48ÞF
35 Min
D5GE
D5NHE
D5NGE
32ÞF
24ÞF
—
6 Hrs
—
—
—
48ÞF
40 Min
Application
MEAT, DELI, DAIRY, P
RE
-
CUT
& P
KG
DAIRY / DELICATESSEN
Return to Contents