background image

C

B

A

E

D

F

C

P/N 0490770_B

M1XLD-GE

Technical Data Sheet

P/N 0490770_B

NSF

®

Certified

March  2008

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

©2008 HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Standard Fan Assembly 

(1)

0440420

Fan Motor, Evaporator

(MO.4410302)

0376413

Fan Blade (FB.0376413)

0123592

Relay, DPDT 208V coil 

(4)

(RL.4440495)

0253603

Relay, DPDT 120V coil 

(RL.4440267)

B.

Optional Adjustable 

Refrigeration Thermostat

(2)

C. 0398557

Standard Non-adjustable

(3)

Defrost Thermostat

(CT.4440611)

Item Part #

Description

Wiring Item #

H

EATERS

D. 0483959

4 ft, 8 ft and 12 ft

(5)

Modular Electric

Defrost Heaters, 208V, 685W

(HE.4850633)

E. Rear Rail Heaters

(6)

0415540

4 foot case (HE.4850482)

0109417

8 foot case (HE.4850422)

0109418

12 foot case (HE.4850423)

F.

0483952

Front Glass Anti-Sweat Heater

(7)

(GL.4978826)

L

AMPS AND

B

ALLASTS

None

Note:  Revision B adds capacity and weight (

Page 5

).

Содержание M1XLD-GE

Страница 1: ...iring Item FAN ASSEMBLIES AND THERMOSTATS A 9W Standard Fan Assembly 1 0440420 Fan Motor Evaporator MO 4410302 0376413 Fan Blade FB 0376413 0123592 Relay DPDT 208V coil 4 RL 4440495 0253603 Relay DPDT...

Страница 2: ...f external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70...

Страница 3: ...E 4 ft 0 9 6 ft NA 8 ft 1 7 12 ft 2 3 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound 3 of 7 P N 0490770_B HUSSMANN CORPORATION BRIDGETON...

Страница 4: ...rent Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Nosing Anti sweat Heaters 120V 50Hz 60Hz Standard 0 40 0 50 0 80 1 00 48 60 96 120 Return Glass Anti sweat Heaters 120...

Страница 5: ...Cu Ft Ft 1 93 ft3 ft 0 18 m3 m ARI Total Display Area 3 Sq Ft Ft 2 57 ft2 ft 0 78 m2 m Shelf Area 4 Sq Ft Ft 2 51 ft2 ft 0 76 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft...

Страница 6: ...y 1 Blue WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only R Red 120V POWER Fron...

Страница 7: ...t Timer 120V Only Blue L3 Yellow Relay 1 WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot m...