MERCHANDISER SETTINGS (Cont'd)
CONTROL SETTINGS
September 1, 1997
7 - 16
HUSSM ANN CORPORATION • BRIDGETON, M O 63044-2483 • Printed in USA
Models
For all Merchandisers
with Gravity Coils, the
Temperature listed in
the "Discharge Air"
row is
Product
Temperature
.
Refrigeration
Discharge Air
Temperature ÞF
Evaporator
TemperatureÞF
Fan Cycling
CI/CO ÞF
Defrost
Frequency
Electric
Temp TermÞF
Failsafe Min
Reverse Air
Temp TermÞF
Failsafe Min
Koolgas
Duration Min
Offtime
Temp TermÞF
Duration Min
DMD
DMDH
DMDA
NDD5
NDD5H
NDD5A
32ÞF
18ÞF
—
6 Hrs
—
—
48ÞF
40 Min
14 Min
—
40 Min
RDM
RDMH
30ÞF
20ÞF
—
24 Hrs
—
—
—
—
12 Min
—
60 Min
CWI
CWI6
MWI
MWI6
30ÞF
20ÞF
—
6 Hrs
—
—
—
—
14 Min
—
56 Min
FHM
FHMG
FHMH
FHMGH
FHMS
FHMSG
MHF
MHFG
MHFGH
NM3
NM3G
NM4
NM4G
NDD3
NDD3G
NDD4
NDD4G
32ÞF
20ÞF
28/38ÞF
6 Hrs
—
—
48ÞF
40 Min
14 Min
—
40 Min
FM
FMG
FMV
FMGV
FMGC
VFMGC
FMGCD
NM1
NM1G
30ÞF
25ÞF
28/38ÞF
12 Hrs
48ÞF
70 Min
—
—
14 Min
—
70 Min
RMA
RMFA
NRD
NRFL
NRDV
NRFLV
30ÞF
23ÞF
—
24 Hrs
—
—
—
—
12 Min
—
60 Min
VBL
VBS
VBK
VBT
NVBA
NVBB
NVBC
34ÞF
20ÞF
—
24 Hrs
—
—
—
—
—
—
60 Min
VGL
VGK
VGS
VGLR
VGSR
NVGB
NVGC
NVGA
38ÞF
20ÞF
—
24 Hrs
—
—
—
—
—
—
110 Min
CGDMG
CGDMGT
CSDMG
NEGDF
NEGSF
NEGDT
25ÞF
21ÞF
—
24 Hrs
—
—
—
—
—
—
90 Min
Application
DELI and CHEESE