6-4
s
ErvIcE
P/N 3053328_C
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
SERVICING VERTICAL LIGHTING
Refer to door manufacturer’s manual for servicing of
vertical lamps.
SERVICING DOORS AND FRAMES
See door manufacturer’s service manual for servicing
information. One manual is shipped with each
merchandiser.
Hussmann’s Innovator Door manual (P/N 0425683)
can be found on the website
www
.
hussmann
.
com
.
REPLACING DOOR OR DOOR FRAME
PARTS
Parts for Reach-in doors and door frame assemblies
must be ordered direct from the door manufacturer
This includes the glass doors, door frame assemblies,
lamps, ballasts, door handles, hold open slides, and
power cords.
Refer to specific warranty supplied with the door.
The manufacturers have a warranty against moisture
penetration, a warranty against tempered glass
breakage, and a warranty on ballasts. Lamps are not
covered by Hussmann or the door manufacturer.
REPLACING DAMAGED DRAIN
FITTING
The following procedure is for the field repair of a
broken drain fitting.
1. Use a drill with a 1
7
/
8
-inch (48 mm) hole saw to
drill out the bottom of the drain fitting. Be sure to
drill completely through fitting and bottom liner.
2. Insert adapter into drain fitting.
Do NOT use
thread sealer on ABS drain fitting. If sealer is used the
ABS drain fitting may crack or leak!
(Tee should be tightened no more than 4 turns.) Do
not overtighten threads.
Drain Fitting
Viewed from Inside Merchandiser
Drain Fitting Viewed from Inside Case
Do NOT use Thread Sealer on Drain Fitting!
End Section View
Foam Bottom
Assembly
Modified Drain
Fitting
PVC Adapter
1
1
/
2
x 1
1
/
4
in.
(38 x 32 mm)
(obtained at local building
supply store)
Tee
1
1
/
4
in. TxSxS
(32 mm)
Do NOT use Thread Sealer on Drain Fitting!