P/N 3053328_C 3-3
Reach-In
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
4. Install remaining PVC drain parts using
recommended PVC cleaner, primer and cement
per manufacturer’s recommendations.
5. Thread plug into the adapter until snug but not
to exceed four full rotations.
6. Installed drip piping may require additional
support depending on the number and location of
the hub floor drains. The installer should always
provide adequate support to all drip piping
arrangements to prevent excess stress on all drip
piping components. The installer must provide
additional support when “evac” type waste water
systems are applied.
It is the installing contractor’s responsibility
to consult local agencies for local code
requirements.
Water Seal
Correct
Water Seal
NOT Correct