display module allows only 10 (ten) of the sensors to be
connected simultaneously. At this time, there is no known
application where all 10 sensors or all available sensors
would be applied.
The order in which the temps are displayed is dependent
upon which sensing devices are installed, as represented
to the right. Missing or non-connected sensors will not
appear in the designated sequence.
Average temperatures are available to view so long as the
associated sensing devices are attached.
DSAV= Discharge Air Average
RTAV=Return Air Average
PDAV=Product Average
T-LO=Lowest Termination Sensor Reading
ILET=Evaporator Inlet
OLET=Evaporator Outlet
TSNL=Left Termination Sensor
TSNC=Center Termination Sensor
TSNR=Right Termination Sensor
DSCL= Discharge Air Left
DSCC=Discharge Air Center
DSCR=Discharge Air Right
RETR= Return Air Right
RETC=Return Air Center
RETL= Return Air Left
PRDR=Product Right
PRDC=Product Center
PRDL=Product Left
ANTI=Anti-sweat Heater temp
PRES-LO=0-200 PSI
TEMP-LO=0-200PSI liquid temp
PRES-HI=0-500 PSI
TEMP-HI=0-500 PSI liquid temp
Controlled load Volts
Controlled load Amps
Controlled Load Power factor
4-39
P/N 0461391A
Hussmann Corporation • Bridgeton, Missouri 63044-2483 U.S.A.
Safe-NET™
TEMPS
DSAV
RTAV
PDAV
T-LO
ILET
OLET
TSNL
TSNC
TSNR
DSCL
DSCC
DSCR
RETR
RETC
RETL
PRDR
PRDC
PRDL
ANTI
PRES-LO
TEMP-LO
PRES-HI
TEMP-HI
VOLTS
AMPS
PF
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Value
Menu Structure — TEMPS
Содержание ARL
Страница 43: ...4 28 P N 0461391A MENUS ...