Port Duplex : FULL
Product Ver : S5700
Step 3
Configure NTDP.
# On devices, enable NTDP in the system view and on the interface and configure the interval
and range for NTDP to collect topologies to 10 minutes and 3 hops respectively.
# Configure the administrator switch.
[Administrator-1]
ntdp enable
[Administrator-1]
ntdp timer 10
[Administrator-1]
ntdp hop 3
[Administrator-1]
interface gigabitethernet 0/0/1
[Administrator-1-GigabitEthernet0/0/1]
ntdp enable
[Administrator-1-GigabitEthernet0/0/1]
quit
[Administrator-1]
interface gigabitethernet 0/0/2
[Administrator-1-GigabitEthernet0/0/2]
ntdp enable
[Administrator-1-GigabitEthernet0/0/2]
quit
# Configure member switch 1.
[Member-1]
ntdp enable
[Member-1]
ntdp timer 10
[Member-1]
ntdp hop 3
[Member-1]
interface gigabitethernet 0/0/1
[Member-1-GigabitEthernet0/0/1]
ntdp enable
[Member-1-GigabitEthernet0/0/1]
quit
[Member-1]
interface gigabitethernet 0/0/2
[Member-1-GigabitEthernet0/0/2]
ntdp enable
[Member-1-GigabitEthernet0/0/2]
quit
# Configure member switch 2.
[Member-2]
ntdp enable
[Member-2]
ntdp timer 10
[Member-2]
ntdp hop 3
[Member-2]
interface gigabitethernet 0/0/1
[Member-2-GigabitEthernet0/0/1]
ntdp enable
[Member-2-GigabitEthernet0/0/1]
quit
# Configure member switch 3.
[Member-3]
ntdp enable
[Member-3]
ntdp timer 10
[Member-3]
ntdp hop 3
[Member-3]
interface gigabitethernet 0/0/1
[Member-3-GigabitEthernet0/0/1]
ntdp enable
[Member-3-GigabitEthernet0/0/1]
quit
After the previous configuration, globally check the NTDP configuration on the administrator
switch. You can find that the interval and range for NTDP to collect topologies is 10 minutes
and 3 hops respectively.
[Administrator-1]
display ntdp
Network topology discovery protocol is enabled
Hops : 3
Timer : 10 min
Hop Delay : 200 ms
Port Delay: 20 ms
Total time for last collection:0 ms
Step 4
Enable the cluster function and set the management VLAN.
# Configure the administrator switch.
[Administrator-1]
cluster enable
[Administrator-1]
cluster
[Administrator-1-cluster]
mngvlanid 10
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management
3 HGMP Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
202