Example
If the incremental configuration command is successfully delivered to member switches, run the
display cluster-increment-result
command, and you can view that
success
is displayed.
<HUAWEI_0.Quidway>
display cluster-increment-result
The result of member switches executing increment commands:
------------------------------------------------------------------------------
SN Device MacAddress IpAddress Result CommandId
------------------------------------------------------------------------------
2 S5700 0003-0003-0003 10.0.0.3
success
-
3 S5700 0004-0004-0004 10.0.0.4
success
-
Run the
display cluster-license
command, and you can check the contents of the cluster license,
including the number of member switches that can be managed by the administrator switch and
maximum layers that member switches can concatenate.
<Quidway>
display cluster-license
The max numbers and hops of manage member switch:
-------------------------------------------------------------
Max numbers of manage member switch: 255
Max hops of manage member switch : 16
Run the
display cluster-topology-info
command, and you can view the cluster topology,
including the topology of normal links, candidate links, and faulty links.
<Quidway>
display cluster-topology-info
<-->:normal device <++>:candidate device <??>:lost device
-------------------------------------------------------------------------
Total topology node number is 5.
[HUAWEI_0.Administrator: Root-00e0-ad14-c600]
|-(GigabitEthernet0/0/1)<-->(GigabitEthernet0/0/1)[HUAWEI_3.Member-3: 00e0-
da1c-4c00]
| |-(GigabitEthernet0/0/2)<-->(GigabitEthernet0/0/1)[HUAWEI_2.Member-2:
00e0-875b-8f00]
| | |-(GigabitEthernet0/0/2)<-->(GigabitEthernet0/0/1)[HUAWEI_1.Member-1:
00e0-0f68-6f00]
|-(GigabitEthernet0/0/2)<-->(GigabitEthernet0/0/1)[HUAWEI_4.Member-4:
00e0-9f7e-0b00]
Run the
display increment-command
command, and you can check the incremental
configuration of the cluster, including the number and contents of the incremental configuration.
<Quidway>
display increment-command
The content of increment commands:
------------------------------------------------------------------------------
SN Content
------------------------------------------------------------------------------
10 vlan batch 10 to 20
20 ip route-static 2.0.0.0 8 10.0.0.1
If the configuration files of member switches are successfully synchronized with the FTP server,
run the
display increment-synchronization-result
command, and you can view that
success
is displayed.
<Quidway>
display increment-synchronization-result
The result of member switches' synchronization:
------------------------------------------------------------------------------
SN Device MacAddress IpAddress result
------------------------------------------------------------------------------
1 S5700 0002-0002-0002 10.0.0.2 success
2 S5700 0003-0003-0003 10.0.0.3 success
3 S5700 0004-0004-0004 10.0.0.4 success
If member switches successfully obtain configuration files, PAF files, or patch files, run the
display member-getfile-state
command, and you can view that
success
is displayed.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management
3 HGMP Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
106