Command Manual – Security
Quidway S8500 Series Routing Switches
Chapter 2 AAA and RADIUS/HWTACACS Protocol
Configuration Commands
Huawei Technologies Proprietary
2-41
Description
Use the
retry stop-accounting
command to configure the maximal retransmission
times after a stop-accounting request is saved into the buffer due to getting no
response.
Use the
undo retry stop-accounting
command to restore the retransmission times to
the default value.
Because the stopping accounting request concerns account balance and will affect the
amount of charge, which is very important for both the user and ISP, NAS shall make its
best effort to send the message to RADIUS accounting server. Accordingly, if the
message from the switch to RADIUS accounting server has not been responded, the
switch shall save it in the local buffer and retransmit it until the server responds or
discard the messages after transmitting for specified times.
Related command:
reset stop-accounting-buffer
,
radius scheme
,
display
stop-accounting-buffer
.
Example
#Perform the following configuration such that the switch can retransmit a buffered
stop-accounting request to the server configured for the RADIUS scheme “Huawei” for
up to 1000 times
[Quidway-radius-huawei] retry stop-accounting 1000
2.2.21 secondary accounting
Syntax
secondary accounting ip-address
[
port-number
]
undo secondary accounting
View
RADIUS scheme view
Parameter
ip-address
: IP address, in dotted decimal format. By default, the IP addresses of
secondary accounting server is at 0.0.0.0.
port-number
: Specifies the UDP port number, ranging from 1 to 65535. By default, the
accounting service is provided via UDP 1813.
Description
Use the
secondary accounting
command to configure the IP address and port
number for the secondary RADIUS accounting server.
Содержание Quidway S8500 Series
Страница 53: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Port Huawei Technologies Proprietary ...
Страница 145: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual VLAN QinQ Huawei Technologies Proprietary ...
Страница 184: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Network Protocol Huawei Technologies Proprietary ...
Страница 276: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Routing Protocol Huawei Technologies Proprietary ...
Страница 493: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Multicast Protocol Huawei Technologies Proprietary ...
Страница 622: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual QoS ACL Huawei Technologies Proprietary ...
Страница 706: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual MPLS Huawei Technologies Proprietary ...
Страница 816: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual STP Huawei Technologies Proprietary ...
Страница 867: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Security Huawei Technologies Proprietary ...
Страница 953: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Reliability Huawei Technologies Proprietary ...
Страница 972: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual System Management Huawei Technologies Proprietary ...
Страница 1180: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual PoE Huawei Technologies Proprietary ...
Страница 1198: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual NAT URPF VPLS Huawei Technologies Proprietary ...
Страница 1238: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Integrated Management Huawei Technologies Proprietary ...
Страница 1300: ...HUAWEI Quidway S8500 Series Routing Switches Command Manual Appendix Huawei Technologies Proprietary ...