Check Item
Normal
Abnormal
Switch
The equipment is stably placed
in the cabinet without shaking.
The equipment is slanted and
loosened.
AS
The equipment is stably placed
in the cabinet without shaking.
The equipment is slanted and
loosened.
Maintenance
terminal
The equipment is stably placed
in the cabinet without shaking.
The equipment is slanted and
loosened.
2.2.2 Checking Cable Connections
Before configuring the VIS6000, you need to check cable connections.
CAUTION
Before checking cable connections, shut down all the power supplies to avoid damage to the
human body or the device caused by improper installation or connections.
Check whether the cables are correctly connected according to the description in
Table 2-3
Description of checking cable connections
Check Item
Normal
Abnormal
Power cable
l
Power cables are connected to the
power supplies of the VIS6000 in
redundancy mode.
l
The power supplies of switches,
ASs, maintenance terminals, and
storage arrays are connected as
required.
l
The power supply of the
VIS6000 is not connected in
redundancy mode, or the live
line, neutral line, or the
grounding line is connected
improperly.
l
The power supplies of switches,
ASs, maintenance terminals, and
storage arrays are not connected
as required, or the live line,
neutral line, or the grounding
line are connected improperly.
Grounding
cable
l
The grounding cable is connected
and fastened to the wiring clip of
the VIS6000 and grounding
connector of the cabinet.
l
The switches, ASs, maintenance
terminals, and storage arrays are
grounded as required.
l
The grounding cable is not
connected to the wiring clip of
the VIS6000 and grounding
connector of the cabinet, or is
loosened.
l
The switches, ASs, maintenance
terminals, and storage arrays are
not grounded as required.
2 Check Before the Configuration
OceanStor VIS6000 Series Virtual Intelligent Storage
System
Initial Configuration Guide
2-4
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 08 (2010-05-10)