Figure 6-36
Configuring Camera NTP Synchronization
4.
In the search results, click
Edit
in the row where
Parameter Name
is
NTPIPC
and set
Value
to 1.
5.
Click
Save
. After the camera NTP synchronization function is enabled, the camera, after
being connected to the server, will automatically time-synchronize with the server.
----End
Follow-up Procedure
The VCN automatically restarts after the IP address is modified. The restart takes about 5
minutes. After the restart, use the new IP address to access the VCN.
Change the PC IP address to an address in the network segment of the new VCN IP
address, enter the VCN IP address in the address box of the Internet browser, and log in
to the OMU Portal system.
(Optional) Deploying IVS in Stack Mode. For details, log in to the
https://e.huawei.com/
, search for the VCN product documentation, open the
documentation, and see the section
(Optional) Deploying IVS in Stack Mode
.
(Optional) Deploying MPUs in Cluster Mode. For details, log in to the
https://e.huawei.com/
, search for the VCN product documentation, open the
documentation, and see the section
(Optional) Deploying MPUs in Cluster Mode
.
For the VCN500, search for
VCN500 Product Documentation
. For the VCN540, search for
VCN510&VCN520&VCN540 Product Documentation
.
6.6.5.5 Setting Parameters on the VCN IVS Client
Prerequisites
The network communication between the VCN and the camera is normal.
Procedure
Step 1
Install the VCN IVS client.
1.
Download the VCN IVS client.
You can obtain the VCN IVS in either of the following ways:
Method 1
Obtain the
HW_IVS_Client.exe
file from the software CD-ROM delivered
with the VCN.
Method 2
1.
Log in to the VCN OMU Portal, choose
Local Configuration
>
Basic
Configuration
, and view
Current version
.