04/2013
2.990.999.120_en
47
SP 5080
5.2
Maintenance of the combined press
5.2.1
Changing the hydraulic fl uid / venting fi lter
Change the hydraulic fl uid and the venting fi lter
every 2 years
– Run the press ram to its rear limit position
– Turn off the main switch and disconnect the red CEE power plug
– Disassemble the shredder press combination
(see “Assembling the shredder press combination” section)
– Remove the cover (H)
Venting fi lter
Part. no. 6.116.195.090
H
– Remove the tank cover and extract the oil with an oil suction unit
• The capacity of the hydraulic fl uid tank is ~ 20 l
– If the tank is very dirty, clean it
– Mount the tank cover onto the unit again
– Add oil until a level between the notches on the oil level dipstick is reached
Oil grade:
• in accordance with DIN 51524-T3 multi-grade oil / ISO viscosity grade HVLP 22
Mineralöle
Mineral oils
ISO VG 22
HVLP
ISO-
Viskositäts-
klasse
ARAL
BP
ESSO
DEA
FINA
Aral Vitam
HF 22
Bartran
HV 22
UNIVIS
N 22
Astron
ZHLP 22
HYDRAN
HV 22
Tellus Öl
T 22
SHELL