30
2.990.999.120_en
04/2013
SP 5080
Service menu / +/– Keys (10)
The service menu can only be called up in manual mode.
Simultaneously press the +/– keys for approx. 3 seconds to access
the
Service
menu item
Use the +/– keys to scroll through the sub-menu items
Set-up mode – Daily bale meter – Total bale meter – Service hours meter – User
language – Error memory – System
.
Simultaneously press the +/– keys again for approx. 3 seconds whilst in the relevant submenu
item, to gain further access within these menus.
Press the +/– keys to scroll through the menus.
Simultaneously press the +/– keys to confi rm the values set.
Press any key to return to the main menu.
SERVICE
4.1.1
Accessing the SERVICE menu
SERVICE
3 sec.
SERVICE
3 sec.
Sub-menu items
SERVICE
Set-up mode >>
Caution!
Set-up mode
Daily bale meter >>
Bale count: xxx
clear? yes/no
Total bale meter >>
Bale count: xxx
Service hours meter >>
Service hours: xxx
User language >>
GB
(D, F, ...)
Error memory >>
XXXX
System >>
Menu timing
Содержание SP 5080
Страница 18: ...18 2 990 999 120_en 04 2013 SP 5080 2 7 Machine dimensions 2 x1 5 kN 2 x1 5 kN 2 x2 3 kN 2 x2 3 kN ...
Страница 38: ...38 2 990 999 120_en 04 2013 SP 5080 1 2 3 4 5 6 7 8 ...
Страница 55: ...04 2013 2 990 999 120_en 55 SP 5080 9 Electrical circuit diagrams Electrical plan is separate in the press ...