04/2013
2.990.999.120_en
31
SP 5080
4.1.2 Set-up
mode
4.1.2.1 Pressure plate forward-backward / door lock open-close
–
Press the +/– keys simultaneously for about 3 seconds
Indicator: Service menu – Set-up mode
–
Simultaneously press the +/– keys again for about 3 seconds
Indicator: Caution! – Set-up mode (fl ashes)
Two hand control: Open the hydraulic door lock (5 + 12)
If you simultaneously press the two keys (within 0.6 seconds), the door lock is opened.
If you let go of one of these keys, the action stops
Two hand control: Close the hydraulic door lock (5 + 12)
If you simultaneously press the two keys (within 0.6 seconds), the door lock is closed.
If you let go of one of these keys, the action stops
Two hand control: Press ram forward (5 + 12)
If you simultaneously press the two keys (within 0.6 seconds), you can run the press
ram forwards whilst the counter plate is open. If you let go of one of these keys, the
press ram stops.
Two hand control: Press ram backward (7 + 12)
If you simultaneously press the two keys (within 0.6 seconds), you can run the press ram
backwards whilst the counter plate is open. If you let go of one of these keys, the press
ram stops.
4.1.2.2 To exit set-up mode
–
Simultaneously press the keys “Close the hydraulic door lock” for about 5 seconds
Содержание SP 5080
Страница 18: ...18 2 990 999 120_en 04 2013 SP 5080 2 7 Machine dimensions 2 x1 5 kN 2 x1 5 kN 2 x2 3 kN 2 x2 3 kN ...
Страница 38: ...38 2 990 999 120_en 04 2013 SP 5080 1 2 3 4 5 6 7 8 ...
Страница 55: ...04 2013 2 990 999 120_en 55 SP 5080 9 Electrical circuit diagrams Electrical plan is separate in the press ...
Страница 56: ...56 2 990 999 120_en 04 2013 SP 5080 10 KP 80 hydraulic diagram ...