04/2013
2.990.999.120_en
43
SP 5080
4.6
Malfunctions of the baling press
As soon as a malfunction occurs in the baling press, the red malfunction symbol lights
up. The baling press and shredder switch off and the relevant error message appears in
the text display.
The “Baling press status” symbol
lights up red on the shredder.
The error number of the most recent error is stored in the error memory.
Diverse, displayed error messages can be cleared by simultaneously pressing the + / –
keys or by turning the machine on and off.
Service - Hotline: +49 75 54/2100-300
4.6.1 Error
numbers
Code
Description
Remedy
1000
One of the phases is missing / power input
Electrician! Check the fuses on site.
1010
A phase is wrong / counter-clockwise phase rotation
Electrician! Phase sequence on site / check phase rotation.
1100
Oil temperature too high
Let oil cool / check oil temperature sensor
1110
Defective oil temperature sensor
Electrician! Replace sensor
1200
Motor overload switch was triggered. Motor too hot
Check motor / reset motor overload switch
1210
Emergency stop on the press has been activated
Unlock the emergency stop button
1211
Emergency stop on the shredder has been activated
Unlock the emergency stop button
1221
Service door in the fi lling area of the press is open
Close the inspection fl ap
1231
Defective “Counter fl ap closed” switch
Electrician! Consult HSM customer service
1232
Counter fl ap is open
Close the counter fl ap
1241
Defective “Counter fl ap 90° open” switch
Electrician! Consult HSM customer service
1271
“Extend press ram” timing
Check the movement of the press ram
1272
“Retract press ram” timing
Check the movement of the press ram
1280
Counter plate not locked
Electrician! Consult HSM customer service
1281
Defective “Bale ready” inductive switch
Electrician! Consult HSM customer service
1285
Defective counter plate locked inductive switch
Electrician! Consult HSM customer service
1300
Defective hardware
Electrician! Consult HSM customer service
1310
Short-circuit master output stage
Electrician! Consult HSM customer service
1320
Short-circuit slave output stage
Electrician! Consult HSM customer service
Содержание SP 5080
Страница 18: ...18 2 990 999 120_en 04 2013 SP 5080 2 7 Machine dimensions 2 x1 5 kN 2 x1 5 kN 2 x2 3 kN 2 x2 3 kN ...
Страница 38: ...38 2 990 999 120_en 04 2013 SP 5080 1 2 3 4 5 6 7 8 ...
Страница 55: ...04 2013 2 990 999 120_en 55 SP 5080 9 Electrical circuit diagrams Electrical plan is separate in the press ...
Страница 56: ...56 2 990 999 120_en 04 2013 SP 5080 10 KP 80 hydraulic diagram ...