9 Replacing components
184
HSD S.p.A. © - h0108k01a.fm120718
Pay attention to the dosage of the thread-locker liquid. Excessive quantities may
unintentionally obstruct holes and/or adversely affect the operation.
Always use an adequate quantity of thread locking compound and also pressurised
air to make sure that the excess material has been removed.
Calibrate the sensors - see paragraph
9.3 “Replacing and adjusting the sensors”
.
Even if only one segment (petal) breaks, the entire collet must be replaced. All
segments of the collet must have the same identification number.
Consult appendix
B “Spare parts”
for information regarding the codes of the HSK collets and HSK
collet assembly tools.
9.4.3
Check the HSK collet after approximately 100 locking
operations
After replacing the HSK collet, it is advisable to check its operation after approximately 100 locking
operations.
Bring the spindle to the
“Collet open (tool-holder cone ejected)”
condition (see page
140
), then
continue with the procedure.
Check the ejection position (see position
“B”
in table
1
on page
125
);
if the position is correct, move on to
check the next point;
otherwise, if the position is not correct,
loosen the lock screw in the screw dowel
and carry out the entire procedure from
point
7
in paragraph
9.4.2 “Assembling
the HSK collet in the spindle”
.
Check the axial force exerted by the locking device on the tool holder (the use of the Power
check is recommended). If the force measured is less than 70% of the minimum value
indicated in paragraph
7.4 “Tool-holder locking and ejection device”
, proceed as follows:
• Grease the collet again as indicated in paragraph
8.1.7 “Lubricate the HSK collet”
, and
check the axial force on the tool-holder again.
• if the force is still less than 70%, change the collet and check again;
• if the force is still less than 70%, change the clamping device completely.
Check operation of the collet, as indicated.
Failure to check operation of the collet can cause serious danger to the operator as
well as damage the said product.
B
Содержание ES779
Страница 2: ......
Страница 4: ...Information about the publication 4 HSD S p A H5801H0118 fm120718 ...
Страница 12: ...Table of contents 12 HSD S p A H5801H0118TOC fm120718 ...
Страница 13: ...Preliminaries ...
Страница 14: ......
Страница 27: ...Descriptions ...
Страница 28: ......
Страница 88: ...3 Technical specifications and main parts 88 HSD S p A h0102k01a fm120718 ...
Страница 121: ...Adjustment and Maintenance ...
Страница 122: ......
Страница 186: ...9 Replacing components 186 HSD S p A h0108k01a fm120718 ...
Страница 187: ...Appendices ...
Страница 188: ......
Страница 196: ...C Disposal 196 HSD S p A h0109k00a fm120718 ...
Страница 199: ......