216 Library Error Codes
Appendix
82
52H
Incorrect external
SCSI connection.
Library connected to
wrong type of SCSI
bus.
Check the cable configuration (see
Connecting and
Powering on the Library
on page 32).
89
59H
Cleaning cartridge
has expired.
Use a new cleaning cartridge.
90
5AH
Not a cleaning
cartridge.
Insert a cleaning cartridge.
100
64H
Library controller
unable to
communicate with
drive module.
Power cycle the library.
101
65H
Drive module unable
to communicate with
drive.
Power cycle the library.
102
66H
Drive command
timeout on drive
module controller.
Command timeout on 8051.
103
67H
A drive module
controller has failed.
Power cycle the library and re-try. Replace the drive
module if unsuccessful (see
Removing and
Replacing Drive Modules
on page 162).
104
68H
Failed drive module
initialization.
Power cycle the library.
105
69H
Drive module serial
timeout to drive.
Retry command.
110
6EH
Library controller
unable to
communicate with
slave card.
Power cycle the library.
Table 46
Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description
Recovery Method
Содержание Surestore E Tape Library Model 2/20
Страница 1: ...hp surestore tape library 2 20 4 40 6 60 8 80 and 10 100 series user s guide ...
Страница 2: ......
Страница 6: ...4 Updates hp surestore tape library ...
Страница 12: ...10 ...
Страница 116: ...114 Retrieving Library Information Chapter 3 ...
Страница 182: ...180 Upgrading Firmware Chapter 5 ...
Страница 222: ...220 Library Error Codes Appendix ...
Страница 236: ...234 ...
Страница 237: ......