Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded
status if a failure has occurred) or is sent by the device microcontroller, without being polled, to
report a failure.
Active Onboard Administrator Status and Information tab
Table 8 Status information
Description
Item
The overall status of the enclosure. Possible values are Unknown, OK, Degraded, and Failed.
Status
Active or Standby.
Role
The physical bay number where the Onboard Administrator is installed.
Bay Number
The temperature of the enclosure in degrees Fahrenheit.
Temperature
The temperature at which the enclosure reports a status of caution.
Caution Threshold
The temperature at which the enclosure reports a critical status and powers off.
Critical Threshold
Hardware information
Description
Item
The common descriptive name of the Onboard Administrator.
Device Name
The name of the company that manufactured the Onboard Administrator.
Manufacturer
The version of the complex firmware image in the Onboard Administrator.
Complex Firmware
Version
The version of the enclosure hardware.
Hardware Version
The part number to use when ordering an additional or replacement Onboard Administrator.
Part Number
Onboard Administrator Module