Power supply
•
Insight Display
Active to Standby screen
When a second HP Superdome 2 Onboard Administrator is installed, the menu item Active to
Standby appears under the Enclosure Settings tree menu item, and both Onboard Administrators
are visible in the tree menu and in the enclosure view under the Status tab.
If more than one Onboard Administrator is installed in the enclosure, you can manually change
the active Onboard Administrator. This feature can be useful when troubleshooting the Onboard
Administrator or if a second Onboard Administrator is installed with an older firmware version
(and automatic transition is disabled).
To perform a transition:
1.
Click the
Transition Active to Standby
button to force the change. A confirmation screen
appears, confirming the transition.
2.
Close your browser if you are logged on to the active Onboard Administrator.
3.
Click
OK
to proceed, or click
Cancel
to exit without a change.
If only one Onboard Administrator is installed in the enclosure, the Active to Standby menu item
does not appear.
Onboard Administrator Module
Active Onboard Administrator screen
The Active Onboard Administrator screen under the Status and Information tab, has tables that
provide detailed information about your Onboard Administrator.
88
Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices