Value
Description
Item
Management Networking
Name of subnet carrying management traffic.
Subnet Name
IP address used to access the array.
Management IP Address
Netmask for the management subnet.
Management Netmask
IP address of the router or gateway the array will use
to access network resources outside of the configured
subnet.
Default Gateway
Secondary IP Address
Standard, Jumbo, or Custom.
MTU Size
When MTU size is set to Custom, this specifies the size
in bytes.
MTU Bytes
Name of the domain the array will be joining.
Domain Name
Assigned Subnet Port
Additional Subnet Port
Support IP address for controller A.
Diagnostics A IP Address
Support IP address for controller B.
Diagnostics B IP Address
Data Networking
Name of subnet carrying data traffic.
Subnet Name
Port used for data traffic.
Port
Data port IP address.
IP Address
Netmask for the data subnet.
Netmask
Standard, Jumbo, Custom
MTU Size
MTU size in bytes.
MTU
IP address used for iSCSI discovery.
Discovery IP Address
Rack Mount Safety Precautions
Observe these safety precautions when you install the storage array or expansion shelf in a rack.
Table 5: Rack Mount Safety Precautions
Precaution
Consideration
If the array or expansion shelf is installed in a closed or multi-unit rack assembly, the operating temper-
ature might be greater than the ambient (room) temperature. Provide adequate cooling so the rack
environment does not exceed 35°C (95°F) as specified by the rack manufacturer.
Operating Ambient
Temperature
Install the equipment in the rack such that each item has ample air flow required for proper cooling.
Cold air comes into the front of the array (drive side) and is exhausted out the back of the array (controller
side) by the fans. Install the array with the front facing the cold aisle and the back facing the hot aisle
in your environment.
Air Flow