quit
ssh server enable
user-interface vty 0 63
authentication-mode scheme
protocol inbound ssh
quit
user-interface aux 0 1
authentication-mode scheme
quit
save
2 Create the public keys on the switch.
public-key local create rsa
Input the modulus length [default = 1024]:Enter
public-key local create dsa
Input the modulus length [default = 1024]:Enter
public-key local create ecdsa secp256r1
3 SSH to the switch by using <<net_switch1_mgmt_ip>>, the user name admin, and the password
<<net_switch_admin_password>>.
Configure IRF Priority
Configure the domain and IRF parameters. The <<net_switch_domain_id>> value is an arbitrary number,
but it must be unique from other IRF domains.
Procedure
1 From system-view, run the following commands:
irf domain <<net_switch_domain_id>>
irf member 1 priority 32
irf member 2 priority 30
irf mac-address persistent always
Convert the Chassis Working Mode
To configure the interfaces and the switch to use FC or FCoE, you must convert the system working mode.
Before running the commands, make sure that both switches are merged into the IRF fabric.
Procedure
1 From system-view, run the following commands:
system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
The system working mode is changed, please save the configuration and reboot
29