Procedure
1.
2.
Disconnect all peripheral cables from the node.
3.
Remove the node from the chassis
4.
Place the node on a flat, level surface.
5.
If installed in a 2U node,
remove the FlexibleLOM 2U node riser cage assembly
6.
If installed in a 2U node,
remove the three-slot riser cage assembly
7.
.
8.
Open the DIMM slot latches.
9.
Install the DIMM.
CAUTION:
To prevent damage to the server, ensure that all DIMM latches are in closed and locked position
before installing the air baffle.
.
11. Install any removed PCI riser cage assemblies
12. Install the node into the chassis
.
13.
Connect all peripheral cables to the node.
Installing SATA and Mini-SAS cable options
Prerequisites
IMPORTANT:
The HPE Apollo r2800 Chassis does not support nodes using the HPE Dynamic Smart Array B140i
Controller or the HPE P840 Smart Array Controller. Hewlett Packard Enterprise recommends installing
an HPE H240 Host Bus Adapter or HPE P440 Smart Array Controller.
• If using the Dynamic Smart Array B140i Controller, the B140i 1U node SATA cable (PN 800060-B21) or
B140i 2U node SATA cable (PN 800061-B21) must be installed.
• To install a P840 Smart Array controller in a 2U node, two P440/P840 Mini-SAS cable options (PN
798205-B21) are required.
• For more information on the riser board slot specifications, see "
PCIe riser board slot definitions
Installing SATA and Mini-SAS cable options
91
Содержание Apollo 2000 System
Страница 50: ... 1U left rear I O blank 2U rear I O blank 50 Operations ...
Страница 123: ... AMD FirePro S9150 GPU NVIDIA Quadro K4200 GPU or NVIDIA Quadro M4000 GPU Hardware options installation 123 ...
Страница 130: ... AMD FirePro S9150 GPU 11 Install Accelerator 1 into slot 3 AMD FirePro S7150 GPU 130 Hardware options installation ...
Страница 134: ...AMD FirePro S9150 19 Install Accelerator 2 into slot 4 AMD FirePro S7150 GPU 134 Hardware options installation ...