Item
Description
Status
1
Power button/LED
1
Solid green = System on
Flashing green = Performing power on
sequence
Solid amber = System in standby
Off = No power present
2
2
UID button/LED
1
Solid blue = Activated
◦ 1 flash per second = Remote management
or firmware upgrade in progress
◦ 4 flashes per second = iLO manual soft
reboot sequence initiated
◦ 8 flashes per second = iLO manual hard
reboot sequence in progress
Off = Deactivated
3
Health LED
1
Solid green = Normal
Flashing amber = System degraded
Flashing red = System critical
3
4
Do not remove LED
Flashing white = Do not remove the node.
Removing the node may terminate the current
operation and cause data loss.
Off = The node can be removed.
5
iLO activity LED
Green or flashing green = Network activity
Off = No network activity
6
iLO link LED
Green = Linked to network
Off = No network connection
7
NIC link LED
1
Green = Linked to network
Off = No network connection
8
NIC activity LED
1
Green or flashing green = Network activity
Off = No network activity
1
When the LEDs described in this table flash simultaneously, a power fault has occurred. For more
information, see "Power Fault LEDs."
2
Facility power is not present, power cord is not attached, no power supplies are installed, power supply
failure has occurred, or the front I/O cable is disconnected.
3
If the health LED indicates a degraded or critical state, review the system IML or use iLO to review the
system health status.
Power fault LEDs
The following table provides a list of power fault LEDs, and the subsystems that are affected. Not all power
faults are used by all servers.
Power fault LEDs
21
Содержание Apollo 2000 System
Страница 50: ... 1U left rear I O blank 2U rear I O blank 50 Operations ...
Страница 123: ... AMD FirePro S9150 GPU NVIDIA Quadro K4200 GPU or NVIDIA Quadro M4000 GPU Hardware options installation 123 ...
Страница 130: ... AMD FirePro S9150 GPU 11 Install Accelerator 1 into slot 3 AMD FirePro S7150 GPU 130 Hardware options installation ...
Страница 134: ...AMD FirePro S9150 19 Install Accelerator 2 into slot 4 AMD FirePro S7150 GPU 134 Hardware options installation ...