90
Installing Field-replaceable units (FRUs)
Copy the command output into a text file named “SANbefor.txt”. After the DC Director is restored to the
fabric, this information can be used to verify that no unintentional changes have occurred to the fabric.
rsl8-st03-dcx-1:admin>
nsshow
Type Pid COS PortName NodeName TTL
<output truncated>
rsl8-st03-dcx-1:admin>
nsallshow
12 Nx_Ports in the Fabric
<output truncated>
rsl8-st03-dcx-1:admin>
switchshow
switchName: switch
<output truncated>
rsl8-st03-dcx-1:admin>
fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
rsl8-st03-dcx-1:admin>
8.
Type
supportShow
; then, copy the command output into a text file named “
spptshow.txt
”.
NOTE:
The
supportShow
command has a very long output and time for completion. It may last 20
minutes or longer depending on the size of the SAN.
This file provides a backup of all the information that might be required by Technical Support. The
information can be used after the DC Director is restored to the fabric, to verify that no unintentional
changes have occurred to the fabric.
rsl8-st03-dcx-1:admin>
supportshow
version: 6.0.0
<output truncated>
rsl8-st03-dcx-1:admin>
9.
Record the cable connections between the DC Director and the target device and ports (
Table 19
).
Disconnect from network and fabric
To disconnect from the network and fabric:
1.
Shut down the DC Director using the
sysShutdown
command.
rsl8-st03-dcx-1:admin>
sysshutdown
This command will shutdown the operating systems on your switch.
You are required to power-cycle the switch in order to restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
Stopping blade 1
Shutting down the blade....
Stopping blade 4
Shutting down the blade....
Stopping blade 10
Shutting down the blade....
Broadcast message from root (pts/1) Tue Jul 18 14:23:06 2006...
The system is going down for system halt NOW !!
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...