Installing Field-replaceable units (FRUs)
Replacing a Director blade
Slots are numbered from 1 through 12, from left to right when facing the port side of the DC Director.
Director blades can be installed in slots 1 through 4 and 9 through 12.
CAUTION:
Wear a grounded ESD strap when handling a Director blade. Use the grounding connections
above the power connectors on the chassis.
1.
Orient the Director blade so that the ports are at the front of the chassis and the flat side of the blade is
on the left. See
Figure 28
.
2.
(FC8-16, FC8-32, and FC8-48 Director blades)
: Adjust the ejectors to the open position, align the flat
side of the Director blade inside the upper and lower rail guides in the slot, and slide the blade into the
slot until it is firmly seated. See
Figure 28
.
(
FC10-6 Director blade, FC4-16IP, and FR4-18i Director blades
) Open the ejectors to approximately
45 degrees, align the flat side of the Director blade inside the upper and lower rail guides in the slot,
and slide the Director blade into the slot, with
slight
pressure to the left, until it is firmly seated.
IMPORTANT:
At the time of this document’s release, the FC4-16IP is not supported in the DC
Director. The FC4-16IP will be supported in a future version of Fabric OS.
3.
(FC8-16, FC8-32, and FC8-48 Director blades)
: Adjust the ejectors to the closed position by pulling
them away from the center of the blade.
(
FC10-6 Director blade, FC4-16IP Director blades
) Close the ejectors by pushing the handles toward the
center of the Director blade until the ejectors lock. The levering action of the handles seats the Director
blade in the slot.
IMPORTANT:
At the time of this document’s release, the FC4-16IP is not supported in the DC
Director. The FC4-16IP will be supported in a future version of Fabric OS.
4.
(FC8-16, FC8-32, and FC8-48 Director blades)
: Adjust the ejectors to the closed position by pulling
them away from the center of the Director blade.
(
FC10-6 Director blade, FC4-16IP, and FR4-18i Director blades
) Tighten the thumb screw inside each
handle using the Phillips screwdriver. See
Figure 28
.
IMPORTANT:
At the time of this document’s release, the FC4-16IP is not supported in the DC
Director. The FC4-16IP will be supported in a future version of Fabric OS.
5.
(
FC10-6 Director blade, FC4-16IP, and FR4-18i Director blades
) Turn the Director blade on by sliding
the slider switch in the top ejector up, covering the thumb screw.
6.
Verify that the power LED on the Director blade is displaying a steady green light. If it does not turn on,
ensure that the Director blade is firmly seated.
7.
Install the SFP or XFP (FC10-6 only) transceivers and cables in the Director blade.
8.
Group and route the cables.
9.
Replace the chassis door. See ”
Replacing the chassis door
” on page 64.
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...