DC SAN Backbone Director hardware reference guide
43
Default IP addresses and password
The default IP addresses and host names for the DC Director are:
•
10.77.77.75 / CP0 (the CP blade in slot 6 at the time of configuration)
•
10.77.77.74 / CP1 (the CP blade in slot 7 at the time of configuration)
The default password is “password”.
IMPORTANT:
Resetting an IP address while the DC Director has active IP traffic such as Fabric Manager,
Fabric Watch, SNMP, or other applications can cause traffic to be interrupted or stopped
To configure the IP addresses for both CP blades (from the active CP blade):
1.
Log in to the active CP as admin using the serial cable connection.
2.
Set up the DC Director IP address by entering the
ipaddrset
-sw 0
command:
swDir:admin>
ipAddrSet -sw 0
Enter the information at the prompts. Specify the
-sw 0
IP address. There is no
-sw 1
IP address.
NOTE:
The addresses 10.0.0.0 through 10.0.0.255 are reserved and used internally by the DC Director.
External IPs must not use these addresses.
3.
Set up the CP0 IP address by entering the
ipaddrset
-cp 0
command:
swDir:admin>
ipAddrSet
-cp 0
Enter the information at the prompts.
4.
Set up the CP1 IP address by entering the
ipaddrset
-cp 1
command:
swDir:admin>
ipAddrSet
-cp 1
Enter the information at the prompts.
This is a sample IP configuration:
swDir:admin> ipaddrset -sw 0
Ethernet IP Address [0.0.0.0]: 123.123.123.120
Ethernet Subnetmask [0.0.0.0]: 123.123.123.123
Fibre Channel IP Address [0.0.0.0]:
Fibre Channel Subnetmask [0.0.0.0]:
Issuing gratuitous ARP...Done.
Committing configuration...Done.
swDir:admin>
ipaddrset
-cp 0
Host Name [cp0]:
Ethernet IP Address [10.77.77.75]: 123.123.123.121
Ethernet Subnetmask [0.0.0.0]: 123.123.123.123
Gateway IP Address [0.0.0.0]: 123.123.123.124
IP address is being changed...Done.
Committing configuration...Done.
swDir:admin> ipaddrset
-cp 1
Host Name [cp1]:
Ethernet IP Address [10.77.77.74]: 123.123.123.122
Ethernet Subnetmask [0.0.0.0]: 123.123.123.123
Gateway IP Address [0.0.0.0]: 123.123.123.124
IP address of remote CP is being changed...Done.
Committing configuration...Done.
swDir:admin> reboot
5.
Type
reboot
to reboot the DC Director.
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...