96
Installing Field-replaceable units (FRUs)
Reconnect system to network and fabric
See the cable routing information recorded in <Link>Table 19 for the following steps:
1.
Connect the CP blades to the local area network:
a.
Insert the appropriate Ethernet cables into each Ethernet port.
b.
Connect the other ends to an Ethernet 10/100 Base-T LAN, if not already connected.
WARNING!
The DC Director can be accessed by remote connection using any of the available
management tools, such as Telnet or Web Tools. Ensure that the DC Director is not modified using other
connections during the rest of this procedure.
2.
Reconnect the transceivers and cables to the port blades:
NOTE:
The ports and cables used in trunking groups must meet specific requirements. For a list of these
requirements, refer to the
HP StorageWorks Fabric OS 6.x administrator guide.
a.
Position one of the transceivers so that the key is oriented correctly to the port and insert the
transceiver into the port until it is firmly seated and the latching mechanism clicks.
b.
Select the cable that corresponds to the port and position it so that the key (the ridge on one side of
the cable connector) is aligned with the slot in the transceiver; then, insert the cable into the
transceiver until the latching mechanism clicks.
c.
Repeat
step 2a
and
step 2c
for the remaining ports.
TIP:
Do not route cables in front of the air exhaust vent (located on the upper port side of the chassis).
d.
Organize the cables as required.
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...