DC SAN Backbone Director hardware reference guide 115
Configuring the FC4-16IP blade
The following sections describe how to get started using the iSCSI target gateway once the blade has been
inserted into the chassis.
There are three levels of configuring the iSCSI blade:
1.
”
Activating iSCSI
” on page 115
2.
”
Activating iSCSI
” on page 115
3.
”
Configuring the IP interface
” on page 116
4.
”
Configuring the FC4-16IP blade
” on page 115
For detailed procedures, see the
HP StorageWorks Fabric OS 6.x administrator guide
.
Activating iSCSI
The chassis-based switch by default disables iSCSI. iSCSI service must be enabled for any iSCSI protocol
operation. An iSCSI virtual target must be created and committed in order for an iSCSI host to connect; no
default iSCSI target is created.
Run the
fosConfig
command to enable iSCSI. Use this command to enable or disable a feature or to
display the current operating status of features on the switch.
fosconfig
[
--enable
feature
|
--disable
feature
] |
[--show
]
args
The following example shows iSCSI service being enabled:
Enabling the persistently disabled ports
Depending on the previous usage of the selected chassis slot, the FC4-16IP ports may be persistently
disabled. Before you can successfully configure the iSCSI Target Gateway, you must persistently enable the
ports.
1.
Enter the
portCfgShow
command to view ports that are persistently disabled. You will need to include
the slot/port argument with
portCfgShow
, for example:
portCfgShow
10/ge3
You could also use the
switchShow
command and parse the output for persistently disabled ports.
2.
After identifying disabled ports, enter the
portCfgPersistentEnable
command on each port to
enable them.
3.
Enter the
portCfgShow
command to verify that ports are persistently enabled.
switch:admin>
fosconfig --enable iscsi
Operation Succeeded.
switch:admin> portcfgshow 7/ge0
Persistent Disable: OFF
Mode: ISCSI
Ipif configuration:
Interface IP
Address
NetMask
MTU
-----------------------------------------------
0 172.1.2.3
255.255.0.0
8250
Arp configuration:
IP Address Mac Address
------------------------------
Iproute Configuration:
IP Address Mask Gateway Metric
----------------------------------------------------
Fciptunnel configuration:
switch:admin>
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...