DC SAN Backbone Director hardware reference guide
45
6.
Type
switchEnable
to reenable the DC Director.
Verify the Port Identifier (PID) mode and connect to the fabric
Before connecting the DC Director to the fabric, verify that the port identifier (PID) mode on the DC Director
matches the other switches in the fabric. This parameter must be identical for all switches in the fabric and
is set using the
configure
command.
To connect the DC Director to the fabric:
1.
Add SFP optical transceivers (or XFP optical transceivers with FC10-6 port card installed) and cables to
the fibre channel ports.
The ports are color-coded to indicate which can be used in the same port group for trunking (trunking
port groups can be up to 8 ports). The ports and cables used in trunking groups must meet specific
requirements. Refer to the
HP StorageWorks Fabric OS 6.x administrator guide
.
2.
Position one of the optical transceivers so that the key is oriented correctly to the port. Insert the
transceiver into the port until it is firmly seated and the latching mechanism clicks.
Transceivers are keyed so that they can only be inserted with the correct orientation. If a transceiver
does not slide in easily, ensure that it is correctly oriented.
3.
Position a cable so that the key (the ridge on one side of the cable connector) is aligned with the slot in
the transceiver. Insert the cable into the transceiver until the latching mechanism clicks.
Cables are keyed so that they can be inserted in only one way. If a cable does not slide in easily,
ensure that it is correctly oriented.
4.
Repeat
step 1
through
step 3
for the remaining ports.
5.
Organize the cables (”
Managing cables
” on page 35).
6.
Verify DC Director and port status using the
switchShow
command.
7.
Verify fabric connectivity using the
fabricShow
command.
Enable software licenses
Depending on the model purchased, certain licenses are factory installed on the DC Director. To determine
which licenses are enabled, use the
licenseShow
command.
swDir:admin>
licenseshow
AAbbccDDeeFFeeGG:
Web license
Zoning license
Extended Fabric license
Fabric Watch license
Performance Monitor license
Trunking license
Security license
In this example, the license key is
AAbbccDDeeFFeeGG
. Keep a copy of the license key for reference.
The 64-bit chassis ID is required to obtain and activate licenses for the DC Director. The chassis ID is
available through the
licenseIdShow
command. The
licenseShow
and
licenseIdShow
commands must be typed through the active CP blade. Refer to the
HP StorageWorks Fabric OS 6.x
administrator guide
.
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...