120 Intelligent blades
:
Defining CHAP entries for iSCSI device authentication
The
modify
command can be used only for changing the authentication method for a target from None to
CHAP or CHAP to None. If nothing is specified, no authentication method is enforced. If CHAP is
specified, then either one-way or mutual CHAP enforcement will be performed based on the login frame
from host.
iscsicfg < --create | --show | --modify | --delete | --clear > auth [-u
username] [–s CHAP_Secret]
args
To modify the authentication method for a target, use the
iscsicfg --modify
command as follows:
:
To create CHAP users, use the
iscsicfg --create
command as follows:
:
Finalizing the iSCSI configuration
Use
commit
with the
iscsiCfg
command to commit the iSCSI changes to persistent memory. This option
triggers propagation of the database to all iSCSI-capable switches in the fabric and blade and commits the
changes to persistent memory.
NOTE:
Make all necessary changes to the database—virtual target creation, LUN additions, discovery
domain creation, discovery domain set creation, and so on—before using the command
iscsicfg
--commit all.
iscsicfg < --commit > all
To commit the configurations that have been created and modified, use the
iscsiCfg
command as
follows:
:
The
iscsicfg –commit all
command commits local configuration changes and also pushes iSCSI
configuration from a local switch to remote switches in the fabric. However, during the commit process,
other configuration changes not yet commited on remote switches need to be aborted. When configuration
changes have been made on switches in the fabric and not yet commited, the
iscsicfg –commit all
command is rejected. You need to manually abort the configuration changes on other switches in the fabric
before trying again to run the command.
To avoid this situation, use the –f option. When you do so, the
iscsicfg –commit all
command runs
and configuration changes not yet commited on remote switches in the fabric are aborted.
switch:admin> iscsicfg –-enable ddset –n myddset
Operation Succeeded
switch:admin> iscsicfg --modify tgt –t iqn.2002-10.com.company.tgt1 –a CHAP -f
Operation Succeeded
switch:admin> iscsicfg –-create auth -u username -s CHAP_Secret
Operation Succeeded
switch:admin> iscsicfg --commit all
This will commit ALL database changes made to all iSCSI switches in fabric.
This could be a long-running operation. Continue [N]:
...
The operation completed successfully
Содержание A7990A - StorageWorks SAN Director 4/16 Blade Switch
Страница 8: ...8 ...
Страница 27: ...DC SAN Backbone Director hardware reference guide 27 I Figure 3 14U Rack Mount Kit contents 26419a ...
Страница 62: ...62 Monitor system components ...
Страница 100: ...100 Installing Field replaceable units FRUs ...
Страница 122: ...122 Intelligent blades ...
Страница 132: ...132 Regulatory compliance and safety notices ...
Страница 134: ...134 Port numbering templates 26390a ...
Страница 135: ...DC SAN Backbone Director hardware reference guide 135 26389a ...
Страница 136: ...136 Port numbering templates 26388a ...
Страница 137: ...DC SAN Backbone Director hardware reference guide 137 FC 10 6 0 2 3 4 5 1 2 3 4 5 FC 10 6 2 3 4 5 1 1 0 0 26391a ...
Страница 140: ...140 Port numbering templates ...