20
To do…
Use the
command…
Remarks
Configure the data
bits
databits
{
5 | 6 | 7
|
8
}
Optional
By default, the data bits of the console port is 8.
Data bits is the number of bits representing one
character. The setting depends on the contexts to be
transmitted. For example, you can set it to 7 if
standard ASCII characters are to be sent, and set it
to 8 if extended ASCII characters are to be sent.
Define a shortcut
key for enabling a
terminal session
activation-key
character
Optional
By default, you can press
Enter
to enable a terminal
session.
Define a shortcut
key for terminating
tasks
escape-key
{
default
|
character }
Optional
By default, you can press
Ctrl+C
to terminate a task.
Configure the flow
control mode
flow-control
{
hardware
|
none
|
software
}
Optional
Configure the type
of terminal display
terminal type
{
ansi | vt100
}
Optional
By default, the terminal display type is ANSI.
The device supports two types of terminal display:
ANSI and VT100. HP recommends you to set the
display type of both the device and the client to
VT100. If the device and the client use different
display types (for example, hyper terminal or Telnet
terminal) or both are set to ANSI, when the total
number of characters of the currently edited
command line exceeds 80, an anomaly such as
cursor corruption or abnormal display of the
terminal display may occur on the client.
Configure the user
privilege level for
login users
user privilege level
level
Optional
By default, the default command level is 3 for the
console user interface.
Set the maximum
number of lines on
the next screen.
screen-length
screen-length
Optional
By default, the next screen displays 24 lines.
A value of 0 disables the function.
Set the size of
history command
buffer
history-command
max-size
value
Optional
By default, the buffer saves 10 history commands at
most.
Set the idle-timeout
timer
idle-timeout
minutes
[
seconds
]
Optional
The default idle-timeout is 10 minutes. The system
automatically terminates the user’s connection if
there is no information interaction between the
device and the user within the idle-timeout time.
Setting idle-timeout to 0 disables the timer.
Содержание A-F5000
Страница 18: ...12 Figure 10 Connection description Figure 11 Specify the serial port used to establish the connection ...
Страница 48: ...42 Figure 29 Connection description Figure 30 Specify the serial port used to establish the connection ...
Страница 52: ...46 Figure 34 Connection Description Figure 35 Enter the phone number ...
Страница 74: ...68 Figure 47 Firefox web browser setting ...