F
or
example,
use
the
following
pro cedure
to
set
the
atness
correction
start
frequency
to
3.5
GHz.
a.
T
yp e
4
3
5
4
.
5
4
5
5
on
the
signal
generator
n
umeric
k
eypad.
b.
T
erminate
the
atness
correction
start
frequency
b
y
selecting
the
NNNNNNNNNNN
GHz
softkey
.
10.
Select
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNN
STOP
FREQ
softkey
in
order
to
en
ter
the
atness
correction
stop
frequency
.
The
display
data
en
try
b o
x
indicates:
Cor
Stop
Frequency
X.XXXXXXXXXGHz
wher
e
X.XXXXXXXXX
is
the
curr
ent
stop
fr
e
quency.
11.
En
ter
the
desired
stop
frequency
.
F
or
example,
use
the
following
pro cedure
to
set
the
atness
correction
stop
frequency
to
9.75
GHz.
a.
T
yp e
4
9
5
4
.
5
4
7
5
4
5
5
on
the
signal
generator
n
umeric
k
eypad.
b.
T
erminate
the
stop
frequency
b
y
selecting
the
NNNNNNNNNNN
GHz
softkey
.
12.
Select
the
NNNNNNNNNNNNNNNNNNNN
POINTS
function
in
order
to
en
ter
the
n
um
b er
of
p oints
to
b e
calibrated.
The
display
indicates:
Set
number
of
points
XX
wher
e
XX
is
the
curr
ent
numb
er
of
p
oints.
13.
En
ter
the
desired
n
um
b er
of
p oints.
Note
that
the
start
and
stop
frequencies
are
include
in
the
n
um
b er
of
p oints.
F
or
example,
use
the
following
pro cedure
to
set
the
n
um
b er
of
p oints
to
100.
a.
T
yp e
4
1
5
4
0
5
4
0
5
on
the
signal
generator
n
umeric
k
eypad.
b.
T
erminate
the
n
um
b er
of
p oints
en
try
b
y
selecting
the
NNNNNNNNNNNNNNNNN
ENTER
softkey
.
14.
Select
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CALIB
FLATCOR
softkey
.
A
t
this
p oint,
the
display
returns
the
CALIB
FLA
TCOR
function
and
the
previous
men
u
function
so
that
y
ou
ha
v
e
the
opp ortunity
to
ab ort
the
atness
correction
routine
and
return
to
the
previous
men
u
if
y
ou
decide
not
to
run
the
routine.
15.
Select
the
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
CALIB
FLATCOR
softkey
(again)
in
order
to
run
the
calibration
routine.
As
the
signal
generator
runs
the
routine,
it
displays
eac
h
frequency
and
p o
w
er
meter
reading.
Note
that
the
signal
generator
sends
the
p o
w
er
meter
eac
h
frequency
p oint
so
that
the
p o
w
er
meter
can
use
the
correct
sensor
calibration
factor
to
determine
p o
w
er
lev
el.
Th
us,
for
highest
accuracy
,
the
correct
calibration
factors
for
y
our
sensor
should
b e
en
tered
in
to
the
p o
w
er
meter.
When
the
signal
generator
completes
the
CALIBRA
TE
FLA
TNESS
CORRECTION
routine,
the
display
returns
to
the
atness
correction
men
u.
16.
T
urn
on
FLA
TNESS
CORRECTION
after
the
routine
is
nished
running
b
y
selecting
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
MORE
2
of
2
and
then
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
FLATCOR
On
Off
so
that
On
is
underscored.
Generating
Signals
3-37
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание 70340A
Страница 94: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 110: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 224: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 261: ...Programming Commands 7 37 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 281: ...Programming Commands 7 57 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 318: ...7 94 Programming Commands Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 323: ...Programming Commands 7 99 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 341: ...Programming Commands 7 117 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 402: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 424: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 436: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...