34 of 61
Indesit
Company
Service Manual UK
English
AUTO TEST
NOTE: -
Before using the AUTO-TEST it is advisable to check the correct operation of the temperature
LEDs in both fridge and freezer display, as these LEDs are used for signalling possible malfunctions.
Ensure the Super Freeze or Holiday modes have not been selected before starting the AUTO-TEST.
STEP 1:
If the appliance has been connected to the mains power for more than 15 minutes,
disconnect it and wait 40 seconds before reconnecting it back to the mains supply.
STEP 2:
Wait until the display completes its set-up and returns to normal operation.
STEP 3:
Open the freezer door.
STEP 4:
Press the freezer light switch 3 times within 10 seconds.
STEP 5:
The test is activated when sequence '07' appears in the freezer temperature display.
*
During the
Damper Check
both the compressor fan and evaporator fan and the compressor will
be ON for at least 15 minutes.
At the end of the Auto Test if all was OK the display will blink
code “00” till the Auto Test is disabled. If 2 or more
checking codes have been recognised the following fault
display codes shall be displayed on fridge display in a rolling
way (each code will show for about 1 second with a 0 in
between the sequence until the Auto Test is disabled).
COMPONENT CHECK
CHECKING
CODE
NOTE
Checking Evaporator De-Frost Heater (3
seconds)
07
Displayed on 2 digit Freezer display
Checking Fridge Probe (3 seconds)
06
Displayed on 2 digit Freezer display
Checking Freezer Probe (3 seconds)
05
Displayed on 2 digit Freezer display
Checking Evaporator Fan (3 seconds)
04
Displayed on 2 digit Freezer display
Checking Compressor Fan (3 seconds)
03
Displayed on 2 digit Freezer display
*Checking Damper/air baffle (see below) (90
seconds)
02
Displayed on 2 digit Freezer display
alternatively to the code “00”
Checking Water Valves
01
Displayed on 2 digit Freezer display
alternatively to the code “00”
Check Ice Valve (2011 NDF Models)
09
Displayed on 2 digit Freezer display
alternatively to the code “00”
Ice Maker Sankyo initialisation without Ice
Valve activation (2011 NDF Models)
12
Displayed on 2 digit Freezer display
alternatively to the code “00”
End of Test
00
To deactivate the Auto test:
Manually switch OFF the power supply
to the appliance or repeat step 4.
Ice Valve & Ice Maker for 2010 DF
models
Not tested on AUTO TEST. This is checked
through the Ice maker and relevant boards
during normal operation. See Ice Maker
Troubleshooting flow chart and Optics Test on
Pages 37 & 38.
Fig. 13