ALARM CONDITIONS
The User Interface Module detects any failures or issues within the appliance. When a failure or issue
is detected the user display will: -
1.
Activates the audible alarm and/or
2.
Brings on a blinking icon and/or
3.
Displays a code on the user display.
The two tables below and overleaf show the ALARM CONDITIONS and DISPLAY CODES.
NOTE: - The User Interface Module turns ON
all
LEDs for 3 seconds after each plug-in. This allows a
visual verification that all the LEDs are properly working. The User Interface Module itself cannot
recognise any failure at this stage. During this time no operations will be allowed (e.g. button pressure,
function engagements).
*If applicable
Type
Buzzer
BLINKING ICON
(Red Triangle)
RESET
Freezer door alarm
Yes (mutes after
approximately 10
minutes)
Freezer door icon
Press the RESET button to stop the buzzer.
Refrigerator door
alarm
Yes (mutes after
approximately 10
minutes)
Refrigerator door
icon
Press the RESET button to stop the buzzer.
Air filter alarm
No
Air filter icon *
Press the RESET button for approximately 3
seconds. Buzzer sound one time.
Water filter alarm
No
Water filter icon
Press the RESET button for approximately 3
seconds. Buzzer sound one time.
-If the water filter has been changed and the
countdown requires resetting during mid or
low stages (i.e. not at alarm stage) this can be
reset at the Autotest end 00 stage by pressing
the water dispenser paddle four times within
10 seconds. The F symbol will display on the
fridge side to confirm the operation. If alarm
display code F is also blinking this will cycle
together.
Over temperature
alarm
Yes (mutes after
approximately 10
minutes)
Alarm icon
Press the RESET button to stop the buzzer.
Long black out alarm
Yes (mutes after
approximately 10
minutes)
Long black out
alarm
Press the RESET button to stop the buzzer.
Failure (any)
Yes (mutes after
approximately 10
minutes)
Alarm icon & letter
code blinks in the
fridge or freezer
display. (See
ALARM CODES
overleaf)
Press the RESET button to stop the buzzer.
(The letter code will not disappear until the
fault or issue has been rectified).