To avoid water overflow, the main module will switch
OFF the relay K002 if the ice valve feedback lasts
more than 20 seconds. The Icemaker system will then
be switched OFF until the following points will be
satisfied:
1) The power has been removed (Power-OFF)
2) The main power has been re-applied (Power-UP)
During this failure condition the main power module will
send the alarm code to the User Interface. (See Alarm
Codes on Pages 31 & 32 Ice maker checks can be
done using the Autotest, see Page 34).
Note:
When the water supply is turned off the Ice
Mode should be disabled on the user control display
interface.
For Ice Maker Troubleshooting see Page 36
SOLENOID VALVE - SANKYO
WATER SOLENOID VALVE MANAGEMENT:
The water solenoid is activated by the display control board passing the information to the Main board.
The control calculates and recorded the total volume of water flowed through the valve during the
opening periods.
The flow rate is:
1.51 litres per minute (24 – 58 cc per second)
Supply voltage (nominal):
220 V AC; 50Hz
Power dissipation for each coil:
20W
Opening voltage:
190 V; 50Hz (at 862 Kpa, 125 psi)
Water pressure range:
1,38 - 8,27 bar
Flow rate outlet Ice Maker:
65cc / 7.5 sec.
Flow rate outlet water dispenser:
237cc / 7.5 sec.
The diagram on Page 18 shows the water flow system:......
Water Solenoid:
8 mm
Blue collar
Ice Maker Solenoid:
6 mm
Yellow collar
Water inlet from filter
Fig. 8