44
PROBLEM POSSIBLE
CAUSE
REMEDY
b) Controller Board
1. Broken.
1. Replace.
1. Dirty Condenser fins.
1. Clean.
2. Ambient temperature
too warm.
2. Check for recommended
temperature.
3. Fan not rotating.
3. See 3 - [1] - a).
4. Refrigerant
overcharged.
4. Recharge.
5. Refrigerant line or
components plugged.
5. Clean and replace Drier.
6. Bad contacts.
6. Check for continuity and
replace.
[3] (Continued)
c) Pressure Switch
7. Loose connections. 7.
Tighten.
1. Loose connections. 1.
Tighten.
2. Motor winding opened
or earthed.
2. Replace.
a) Gear Motor
3. Motor Protector
tripped.
3. Find out the cause of
overheat or overcurrent.
b) Power Supply
1. Circuit Ampacity too
low.
1. Install a larger-sized
conductor.
[4] Compressor
starts, but Gear
Motor will not
operate after 15
seconds.
c) Controller Board
1. Broken.
1. Replace
1. Gas leaks.
1. Check for leaks with a leak
detector. Reweld leak,
replace Drier and
Mechanical Seal, and
charge with refrigerant.
The amount of refrigerant is
marked on Nameplate or
Label.
a) Refrigerant Line
2. Refrigerant line
clogged.
2. Replace the clogged
component.
1. Bad contacts.
1. Check for continuity and
replace.
2. Loose connections. 2.
Tighten.
[5] Gear Motor and
Compressor
start, but no ice
is produced.
b) Line Valve
3. Broken.
3. Replace.
2. LOW ICE PRODUCTION
PROBLEM POSSIBLE
CAUSE
REMEDY
1. Gas leaks.
1. See 1 - [5] - a).
2. Refrigerant line
clogged.
2. Replace the clogged
component.
a) Refrigerant Line
3. Overcharged.
3. Recharge.
1. Dirty Air Filter or
Condenser.
1. Clean.
2. Ambient temperature
too warm.
2. Check for recommended
temperature.
b) High-side
Pressure Too
High
3. Fan rotating too slow.
3. See 3 - [1] - a).
c) Expansion Valve
1. Low-side pressure
exceeding the limit.
1. Adjust or replace.
[1] Low ice
production.
d) Evaporator
1. Evaporator deformed.
1. Replace.
Содержание TM-500AAE
Страница 4: ...iii 8 FLUSH WATER VALVE 59 9 CONTROLLER BOARD 60 10 LINE VALVE 60...
Страница 7: ...3 2 DIMENSIONS CONNECTIONS...
Страница 13: ...9 2 WIRING DIAGRAM a WIRING DIAGRAM...
Страница 14: ...10 b CONTROL BOX LAYOUT...
Страница 24: ...20 d SEQUENCE 1 Startup Water Supply Floor Mounting...
Страница 25: ...21 1 Startup Water Supply Fixed Mounting...
Страница 26: ...22 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Floor Mounting...
Страница 27: ...23 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Fixed Mounting...
Страница 28: ...24 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Floor Mounting...
Страница 29: ...25 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Fixed Mounting...
Страница 30: ...26 4 Startup Ice production starts Floor Mounting...
Страница 31: ...27 4 Startup Ice production starts Fixed Mounting...
Страница 32: ...28 5 Normal Operation Bin control and drain cycle 480 sec start Fixed Mounting...
Страница 33: ...29 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Floor Mounting...
Страница 34: ...30 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Fixed Mounting...
Страница 35: ...31 7 Shutdown Drain Floor Mounting...
Страница 36: ...32 7 Shutdown Drain Fixed Mounting...
Страница 57: ...53 Fig 1 Fig 2 Fig 3...