36
[b] SERVICE OPERATION
(Remove the Front Panel for access to the service buttons)
CAUTION
Removal of the Front Panel will expose moving and hot parts. It is allowed for qualified
service personnel only.
Symbol Button Symbol Button
Option
Floor Mounting
Drum Rotation
Fixed Mounting
1) Drum Rotation Button
When pressed in the STOP mode (including error shutdown), the Drum will rotate
regardless of icemaking process.
2) Displaying Error Record
Keep pressing the Option Button in the ICE or STOP mode.
Press the Stop Button to display the error record.
A maximum of eight most recent errors will be displayed in reverse order of occurrence,
including those not informed to the user (not displayed).
“– –“ shows the end of the error record.
Release the Option Button to return to the original mode.
3) Resetting Error Record
With the Operation Switch in the OFF position, keep pressing the Stop + Option Buttons
together, and turn ON the Operation Switch.
Release the Buttons when the Display Window shows “00”.
The error record has been reset. Do NOT use this command unless necessary.
4) Mounting Mode Options
The mounting mode is usually selected between “floor mounting” and “fixed mounting” at
the time of installation by pressing the Select Switch. If a change is required after
installation, press the Select Switch with the Operation Switch in the OFF position.
Содержание TM-500AAE
Страница 4: ...iii 8 FLUSH WATER VALVE 59 9 CONTROLLER BOARD 60 10 LINE VALVE 60...
Страница 7: ...3 2 DIMENSIONS CONNECTIONS...
Страница 13: ...9 2 WIRING DIAGRAM a WIRING DIAGRAM...
Страница 14: ...10 b CONTROL BOX LAYOUT...
Страница 24: ...20 d SEQUENCE 1 Startup Water Supply Floor Mounting...
Страница 25: ...21 1 Startup Water Supply Fixed Mounting...
Страница 26: ...22 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Floor Mounting...
Страница 27: ...23 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Fixed Mounting...
Страница 28: ...24 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Floor Mounting...
Страница 29: ...25 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Fixed Mounting...
Страница 30: ...26 4 Startup Ice production starts Floor Mounting...
Страница 31: ...27 4 Startup Ice production starts Fixed Mounting...
Страница 32: ...28 5 Normal Operation Bin control and drain cycle 480 sec start Fixed Mounting...
Страница 33: ...29 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Floor Mounting...
Страница 34: ...30 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Fixed Mounting...
Страница 35: ...31 7 Shutdown Drain Floor Mounting...
Страница 36: ...32 7 Shutdown Drain Fixed Mounting...
Страница 57: ...53 Fig 1 Fig 2 Fig 3...