52
6. EVAPORATOR ASSEMBLY
1) Push the Stop Button to drain the water in the Tank.
2) Disconnect the power source.
3) Remove the panels.
4) Unscrew and remove the following parts (see Fig. 1 - 3):
Tank Guide
Spout Switch
Tank Cover (C)
Tank Cover (A) with Heater (Tank)
To completely disconnect it from the unit, loosen the closed end connector or cut the
wire.
Tank Cover (B) with Float Switch
To completely disconnect it from the unit, loosen the closed end connector or cut the
wire. The Float Switch is also removable separately.
Ice Guide
Switch Plate
Ice Guide - Side
Not necessary to remove. The other parts are still removable with this part in place.
Belt Cover
Sensor Cover
After loosening the screws, remove the Sensor Cover by sliding it toward the back
of the unit. Otherwise, the Sensor attached to the Sensor Cover may contact the
Sensor Plate and get damaged.
Sensor Plate
GEAR MOTOR (Fig. 3)
5) Release the Gear Motor together with the Gear Motor Bracket from the Tank, by removing
the three screws and slightly lifting up the assembly. Remove the Belt.
Note: To remove only the Belt for replacement, the three screws on the Gear Motor Bracket
do not need to be removed but should only be loosened.
6) Remove the Gear Motor and the Motor Cover, if necessary. To completely disconnect it
from the unit, loosen the closed end connector or cut the wire.
PULLEY (Fig. 3)
7) Loosen the Hexagon Socket Head Cap Screws, and remove the Pulleys.
Содержание TM-500AAE
Страница 4: ...iii 8 FLUSH WATER VALVE 59 9 CONTROLLER BOARD 60 10 LINE VALVE 60...
Страница 7: ...3 2 DIMENSIONS CONNECTIONS...
Страница 13: ...9 2 WIRING DIAGRAM a WIRING DIAGRAM...
Страница 14: ...10 b CONTROL BOX LAYOUT...
Страница 24: ...20 d SEQUENCE 1 Startup Water Supply Floor Mounting...
Страница 25: ...21 1 Startup Water Supply Fixed Mounting...
Страница 26: ...22 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Floor Mounting...
Страница 27: ...23 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Fixed Mounting...
Страница 28: ...24 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Floor Mounting...
Страница 29: ...25 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Fixed Mounting...
Страница 30: ...26 4 Startup Ice production starts Floor Mounting...
Страница 31: ...27 4 Startup Ice production starts Fixed Mounting...
Страница 32: ...28 5 Normal Operation Bin control and drain cycle 480 sec start Fixed Mounting...
Страница 33: ...29 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Floor Mounting...
Страница 34: ...30 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Fixed Mounting...
Страница 35: ...31 7 Shutdown Drain Floor Mounting...
Страница 36: ...32 7 Shutdown Drain Fixed Mounting...
Страница 57: ...53 Fig 1 Fig 2 Fig 3...