7
5. PERIODICAL CLEANING
1) Machine and Bin Exterior
Wipe the exterior at least once per week with a clean, soft cloth. Use a damp cloth containing a
neutral cleaner to wipe off grease or dirt.
2) Storage Bin Interior Cleaning/Sanitisation (as required) [fixed mounting only]
1) Open the Storage Bin Door, and remove all ice.
2) Wash the Bin Liner, Ice Deflector and Door inner surface with a neutral non-abrasive cleaner.
Rinse thoroughly with a clean cloth and fresh water.
3) Mix 5 litres of water with 18 mL of 5.25% sodium hypochlorite solution in a suitable container
or the recommended Hoshizaki sanitiser as directed.
4) Soak a clean sponge or cloth with the solution and wipe all the surfaces of the Bin Liner, Ice
Deflector and Door inner surface.
5) Rinse thoroughly with fresh water and a clean cloth to wipe off the solution. Close the Bin
Door.
Note: Some solutions may cause damage to the Bin liner surfaces or corrosion on the metal
parts. Always rinse the sanitiser unless directed otherwise by Hoshizaki guidelines.
Содержание TM-500AAE
Страница 4: ...iii 8 FLUSH WATER VALVE 59 9 CONTROLLER BOARD 60 10 LINE VALVE 60...
Страница 7: ...3 2 DIMENSIONS CONNECTIONS...
Страница 13: ...9 2 WIRING DIAGRAM a WIRING DIAGRAM...
Страница 14: ...10 b CONTROL BOX LAYOUT...
Страница 24: ...20 d SEQUENCE 1 Startup Water Supply Floor Mounting...
Страница 25: ...21 1 Startup Water Supply Fixed Mounting...
Страница 26: ...22 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Floor Mounting...
Страница 27: ...23 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Fixed Mounting...
Страница 28: ...24 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Floor Mounting...
Страница 29: ...25 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Fixed Mounting...
Страница 30: ...26 4 Startup Ice production starts Floor Mounting...
Страница 31: ...27 4 Startup Ice production starts Fixed Mounting...
Страница 32: ...28 5 Normal Operation Bin control and drain cycle 480 sec start Fixed Mounting...
Страница 33: ...29 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Floor Mounting...
Страница 34: ...30 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Fixed Mounting...
Страница 35: ...31 7 Shutdown Drain Floor Mounting...
Страница 36: ...32 7 Shutdown Drain Fixed Mounting...
Страница 57: ...53 Fig 1 Fig 2 Fig 3...