4
3. SPECIFICATIONS
AC SUPPLY VOLTAGE
AMPERAGE
STARTING AMPERAGE
ELECTRIC CONSUMPTION
POWER FACTOR
POWER SUPPLY CAPACITY
1 PHASE 230V 50Hz
10.3A
(Ambient temp. 32°C, Water temp. 21°C)
75.9A
2035W
(Ambient temp. 32°C, Water temp. 21°C)
85.6%
Min 4.8kVA (20.9A)
ICE PRODUCTION PER 24h
Thick Ice Thin Ice
Approx. 520 kg
630 kg (Ambient temp. 10°C, Water temp. 10°C)
Approx. 460 kg
550 kg (Ambient temp. 21°C, Water temp. 15°C)
Approx. 380 kg
460 kg (Ambient temp. 32°C, Water temp. 21°C)
WATER CONSUMPTION PER 24h
Thick Ice Thin Ice
Approx. 0.53 m
3
0.64
m
3
(Ambient temp. 10°C, Water temp. 10°C)
Approx. 0.47 m
3
0.56
m
3
(Ambient temp. 21°C, Water temp. 15°C)
Approx. 0.39 m
3
0.47
m
3
(Ambient temp. 32°C, Water temp. 21°C)
SHAPE OF ICE
MAX. STORAGE CAPACITY
Scale Ice
Not Applicable
DIMENSIONS (DRAWING No.)
EXTERIOR
CONNECTION - ELECTRIC
- WATER SUPPLY
- DRAIN
761(W) x 524(D) x 800(H) (362948)
Stainless Steel, Galvanized Steel (Rear)
Y-type Con.
Inlet
G 3/4”
(Connected at rear side)
Outlet
R 3/4”
(Connected at rear side)
ICE MAKING SYSTEM
HARVESTING SYSTEM
Drum type
Continuous ice making system
COMPRESSOR
CONDENSER
HEAT REJECTION
EVAPORATOR
REFRIGERANT CONTROL
REFRIGERANT CHARGE
Hermetic Compressor Model CS20K6E-PFZ
Fin and Tube type, Air-cooled (Fan Motor output 30W)
2980W (Ambient temp. 32°C, Water temp. 21°C)
Aluminum Horizontal Drum
Thermostatic Expansion Valve
R404A 1900g
BIN CONTROL SYSTEM
ICE MAKING WATER CONTROL
Infrared ray Sensor (Time Delay Controlled)
Float Switch and Water Valve
ELECTRICAL PROTECTION
REFRIGERATION CIRCUIT
PROTECTION
GEAR MOTOR PROTECTION
LOW WATER PROTECTION
BIN CONTROL PROTECTION
INTERLOCK
Class I Appliance, 3.15A Fuse
Compressor Internal Motor Protector, Internal Pressure Relief Valve,
Pressure Switch (Auto-reset)
Thermal Protector (Auto-reset), Motor Rotation Protection
Float Switch and Microprocessor
Micro Switch (Manual-reset)
Shutdown by Microprocessor (Manual-reset)
WEIGHT
PACKAGE
Net weight 152 kg / Gross weight 166 kg
Carton 865mm(W) x 700mm(D) x 972mm(H)
ACCESSORIES Installation
Kit
OPTION
Chute, Top Kit
OPERATION CONDITIONS
AMBIENT
TEMP.
WATER SUPPLY TEMP.
WATER SUPPLY PRESSURE
VOLTAGE
RANGE
5-40°C
5-35°C
0.5-8 bar (0.05-0.8MPa)
Rated Voltage ± 10%
We reserve the right to make changes in specifications and design without prior notice.
Содержание TM-500AAE
Страница 4: ...iii 8 FLUSH WATER VALVE 59 9 CONTROLLER BOARD 60 10 LINE VALVE 60...
Страница 7: ...3 2 DIMENSIONS CONNECTIONS...
Страница 13: ...9 2 WIRING DIAGRAM a WIRING DIAGRAM...
Страница 14: ...10 b CONTROL BOX LAYOUT...
Страница 24: ...20 d SEQUENCE 1 Startup Water Supply Floor Mounting...
Страница 25: ...21 1 Startup Water Supply Fixed Mounting...
Страница 26: ...22 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Floor Mounting...
Страница 27: ...23 2 Startup After completion of water supply Fan Motor and Line Valve start in 2 min Fixed Mounting...
Страница 28: ...24 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Floor Mounting...
Страница 29: ...25 3 Startup After Fan Motor and Line Valve start Compressor starts in 15 sec Fixed Mounting...
Страница 30: ...26 4 Startup Ice production starts Floor Mounting...
Страница 31: ...27 4 Startup Ice production starts Fixed Mounting...
Страница 32: ...28 5 Normal Operation Bin control and drain cycle 480 sec start Fixed Mounting...
Страница 33: ...29 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Floor Mounting...
Страница 34: ...30 6 Shutdown After pump down and drain cycle 480 sec start Compressor stops in 5 sec Fixed Mounting...
Страница 35: ...31 7 Shutdown Drain Floor Mounting...
Страница 36: ...32 7 Shutdown Drain Fixed Mounting...
Страница 57: ...53 Fig 1 Fig 2 Fig 3...