![horsch Pronto 6 AS Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/horsch/pronto-6-as/pronto-6-as_operating-instructions-manual_2164110036.webp)
30
Tram line with half-width shut down
If a tram line is required with half-width shut
down enabled, one must consider the installation
position of the valves.
Hoses may need to be replugged or adapted to
the control.
Seed flow monitoring with half-width shut
down
If the switched off half-width is equipped with sen
-
sors for seed flow monitoring, these would indicate
corresponding alarm messages in the terminal.
You can either switch off the seed flow moni
-
toring, or unplug the sensors and correct their
number in the machine configuration.
Note: The sensor numbers can also be entered
into the tram line list. In this case this list would
also need to be updated.
Half-width shut down with one
distributor tower
On all machines with a distributor tower the
half-width can be manually switched with the
distributor cover.
Cover half-width shut down manual
Unscrew the distributor cover and reinsert it into
the tower with the plate facing down.
Make sure that the "correct" side has been shut
down and check the air flow on the coulters of
the still open half with the fan running.
Seed quantity with half-width shut down
With the half-width cover in place the seed quan-
tity in the terminal must be halved.
The seed quantity can be reduced down to 50%:
either via the % adjustment button, or by enter-
ing just half of the desired seed quantity under
"Seed quantity kg/ha".
In both cases the drilled area is counted over
the entire machine width.
If the correct area is strictly required, the working
width must be halved in the machine configura
-
tion. The seed quantity must in this case not be
manually changed.