9. Check for the following:
a) A constant feed water flow.
b) A consistent system pressure.
c) Leaks in the system.
d) Unusual noises or other occurrences.
Shutting Down the Seafari Escape System
The freshwater flush pump is equipped with a pressure switch that will cycle the pump on and off. If
the pump’s outlet pressure is below 45 PSI, the pump will operate; when the pump’s outlet pressure
is above 45 PSI, the pump will stop. The freshwater flush pump will cycle on and off during the
freshwater flush cycle. This is normal and to be expected.
1. Prior to stopping the system, determine if the system will be stored for a period of time or if it will
be operated again soon. Failure to properly flush and or store the system will lead to premature
fouling or drying out of the RO Membrane Element, which is not covered by the Horizon Reverse
Osmosis Warranty and is the liability of the operator of the system.f the system will not be operated
within the next month or longer, perform a long-term storage operation.
a) If the system will be exposed to freezing temperatures, you must follow winterizing procedures.
Freezing temperatures will cause extensive damage if the system is not properly protected.
b) If the system will be operated within the next two weeks, no action is necessary besides
winterization for freezing temperatures.
c) If the system will not be operated within the next two weeks, perform a freshwater flush. If the
Horizon Reverse Osmosis Automatic Freshwater Flush is installed, ensure that the potable
water storage tank has fresh potable water for the freshwater flush to utilize in rinsing the system.
If the system does not include an automatic freshwater flush, perform a manual freshwater flush
of the system.
d) If the system will not be operated within the next month or longer, perform a long-term storage
operation.
2. Stop the system by pressing the “START/STOP” switch once. If the freshwater flush assembly is
installed, the freshwater flush lamp will illuminate, intermittently blinking for 90 minutes. This time
delay is to allow the ETD to dissipate its pressure. After the 90-minute wait period, the freshwater
flush automatic cycle will begin as indicated by a steady, non-blinking illumination of the freshwater
flush lamp.
The freshwater flush pump is equipped with a pressure switch that will cycle the pump on and off.
If the pump’s outlet pressure is below 45 PSI, the pump will operate; when the pump’s outlet
pressure is above 45 PSI, the pump will stop. The freshwater flush pump will cycle on and off during
the freshwater flush cycle. This is normal and to be expected.
The freshwater flush cycle will last for approximately 10 minutes. The 10-minute cycle is adjustable
from 6 to 13 minutes. After the freshwater flush cycle is complete, the freshwater flush lamp will
illuminate, intermittently blinking in the stand-by mode. Every 7 days the freshwater flush rinse
cycle will repeat automatically.
If the “START/STOP” switch is pressed twice, the automatic freshwater flush cycle will be cancelled,
and the freshwater flush lamp will not be illuminated.
3. Close the Inlet Sea Cock Valve. This is a safeguard for vessel installations.
4. If the freshwater flush is installed and activated, do not interrupt power. If the freshwater flush is
not installed or is not activated, turn off the electrical power source (circuit breaker) to the system.
This eliminates the chance of inadvertently starting the system. If the power source has been turned
off, the freshwater flush will not cycle every 7 days.
Seafari Escape 200-600
50
Содержание Seafari Escape 200
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 28: ......
Страница 48: ...________________________________________________________________________________ Seafari Escape 200 600 48...
Страница 73: ...3 8 1 9 2 7 5 4 3 6 Seafari Escape 200 600 74...
Страница 75: ...2 5 7 6 3 4 8 1 6 4 8 3 Seafari Escape 200 600 76...
Страница 77: ...8 4 1 5 3 7 3 2 6 9 4 10 11 Seafari Escape 200 600 78...
Страница 89: ...7 8 6 4 1 3 1 2 4 9 5 Seafari Escape 200 600 90...
Страница 91: ...9 3 6 7 8 10 4 1 1 4 5 5 2 Seafari Escape 200 600 92...
Страница 93: ...13 3 10 11 14 12 8 4 6 7 9 5 1 7 9 2 Seafari Escape 200 600 94...
Страница 95: ...10 18 9 6 15 5 8 16 17 7 14 3 1 20 2 4 11 13 Seafari Escape 200 600 96...
Страница 103: ...5 6 2 3 2 6 7 9 9 8 1 10 5 Seafari Escape 200 600 104...
Страница 110: ...15 9 13 26 12 22 4 20 17 11 6 9 15 9 15 18 10 15 5 3 10 14 16 21 8 25 1 23 19 24 7 2 12 26 111 Exploded Parts View...
Страница 113: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 Seafari Escape 200 600 114...
Страница 116: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 20 19 17 18 117 Exploded Parts View...
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......