Chapter
7
Commissioning a New System
New System Start-up Procedures
1. Ensure that the installation has been properly performed.
2. Ensure that the tube-shipping plug has been removed from the potable water outlet port of the
Water Control Manifold (Compact System) or from the RO Membrane/Vessel Product Water Port
(Modular System) and that all 1/4-inch and 3/8-inch product water tubes are connected.
3. Check the RO Membrane Element as described below.
Note: Some systems are shipped WITHOUT the RO Membrane Element. This is to
accommodate, for example, boat builders who install the system well in advance of
commissioning the boat and the Horizon Reverse Osmosis System.
If the RO Membrane Element has been installed, there will be an Element Serial Number tag
attached to the RO Membrane/Vessel Assembly. Find this serial number tag to ensure that the RO
Membrane Element has been installed.
If the RO Membrane Element Serial Number tag is missing or does not contain a serial number
and date, then immediately contact the company that sold the system to you or Horizon Reverse
Osmosis. Provide Horizon Reverse Osmosis with the system serial number and model number of
this Seafari Escape System.
Caution: DO NOT attempt to operate the system without a RO Membrane Element installed
in the system, as extensive damage will result.
4. Ensure that the manual bypass lever located on the side of the 3-Way Product Water Solenoid
Diversion Valve is positioned outward (away from the coil body).
5. Check each hose and tube connection to the system to ensure that the installer has properly
connected and routed each hose and tube. Ensure that there are no kinks or blockages in any of
the hoses or tubes leading to and from the Seafari Escape System. Improper routing and any
blockage in any line causes damage to the system. Do not rely on the installer’s word; check it
yourself.
6. Make sure that the electrical power source, the boat’s circuit breaker, to the system is switched
"OFF."
7. Open the front panel of the Main Power Enclosure. Check all electrical and electronic connections
for proper wiring and attachment.
8. Ensure that the installer has used the proper-sized power wire and Booster Pump wire.
9. Close the Main Power Enclosure front panel.
10. Open the Sea Cock Valve.
43
Содержание Seafari Escape 200
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 28: ......
Страница 48: ...________________________________________________________________________________ Seafari Escape 200 600 48...
Страница 73: ...3 8 1 9 2 7 5 4 3 6 Seafari Escape 200 600 74...
Страница 75: ...2 5 7 6 3 4 8 1 6 4 8 3 Seafari Escape 200 600 76...
Страница 77: ...8 4 1 5 3 7 3 2 6 9 4 10 11 Seafari Escape 200 600 78...
Страница 89: ...7 8 6 4 1 3 1 2 4 9 5 Seafari Escape 200 600 90...
Страница 91: ...9 3 6 7 8 10 4 1 1 4 5 5 2 Seafari Escape 200 600 92...
Страница 93: ...13 3 10 11 14 12 8 4 6 7 9 5 1 7 9 2 Seafari Escape 200 600 94...
Страница 95: ...10 18 9 6 15 5 8 16 17 7 14 3 1 20 2 4 11 13 Seafari Escape 200 600 96...
Страница 103: ...5 6 2 3 2 6 7 9 9 8 1 10 5 Seafari Escape 200 600 104...
Страница 110: ...15 9 13 26 12 22 4 20 17 11 6 9 15 9 15 18 10 15 5 3 10 14 16 21 8 25 1 23 19 24 7 2 12 26 111 Exploded Parts View...
Страница 113: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 Seafari Escape 200 600 114...
Страница 116: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 20 19 17 18 117 Exploded Parts View...
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......