VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
6-6
Time Window
Number
Start Time
(HH:MM)
Stop Time
(HH:MM)
1
2
3…..20
A time window must have a start and a stop time.
Time Windows Programming
Enter Scheduling Mode by entering
Installer Code + [#] + [80]
. The keypad displays the
Time Window Programming
prompt.
PROMPT
EXPLANATION
Time Window ?
1 = YES 0 = NO
0
Enter
1
at this main menu prompt to program time windows.
Time Window # ?
01-20, 00 = Quit 01
Enter the 2-digit time window number
(01-20)
to be programmed.
Press [
∗
] to accept the entry. Enter
00 + [
∗
]
at the “Time Window #?” prompt to quit time window
programming and display the “Quit ?” prompt.
01 TIME WINDOW
00:00AM 00:00AM
If you entered a time window number, the cursor is now positioned on the tens of hours digit of the start of
window entry.
Enter the desired start of window hour and press [
∗
]. The cursor moves to the minutes position. Enter the
desired minutes and press [
∗
]. Toggle the AM/PM indication by pressing any key 0-9 while the cursor is
under the A/P position and then press [
∗
]. Repeat this to program the stop of window entry.
When the entry is completed, the “Time Window #?” prompt is displayed again.
Enter the next time window number to be programmed and repeat the procedure.
Quit ?
1 = YES 0 = NO
0
Enter
0
at the Quit ? prompt to return to the main menu choices and continue programming.
Enter
1
to quit Scheduling Menu Mode.
Because the time windows are shared among all partitions, it is important to make sure that changing a
time window does not adversely affect desired actions in other partitions.
Daily Open/Close Schedules
Each partition can be assigned one daily open/close schedule, plus a holiday schedule. Temporary schedules are
programmed separately, using the
#81 Temporary Schedule Menu Mode
. To program additional open/close schedules,
see
Time-Driven Events Programming
later in this section for the procedure
.
Open/Close Schedule Worksheet
The following worksheet is an example of the worksheet found in the
Programming Guide.
Write the previously defined
time window numbers for open and close for each partition.
Part
Mon
Tues
Wed
Thur
Fri
Sat
Sun
Hol
Op
Cl
Op
Cl
Op
Cl
Op
Cl
Op
Cl
Op
Cl
Op
Cl
Op
Cl
1
2
3…8
Содержание VISTA-128BPT
Страница 2: ......
Страница 46: ......
Страница 56: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide 4 10 ...
Страница 88: ...V128BPT V250BPT Installation and Setup Guide 8 2 ...
Страница 104: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide C 2 ...
Страница 112: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Glossary 6 ...
Страница 118: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Index 6 ...
Страница 120: ...For the latest warranty information please go to www honeywell com security hsc resources wa ...
Страница 121: ...NOTES ...
Страница 122: ...NOTES ...
Страница 123: ...NOTES ...