VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
5-10
FIELD
TITLE and DATA ENTRIES
EXPLANATION
1
∗
∗
∗
∗
49
Suppress Transmitter
Supervision Sound
0
= disable
1
= enable
If enabled, no trouble soundings occur on the keypad for transmitter check-in
failures.
Must be
0
for UL.
1
∗
∗
∗
∗
52
Send Cancel If Alarm + Off
(partition-specific)
0
= disable
1
= enable
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTES:
This option must be enabled so Cancel reports are always sent.
1
∗
∗
∗
∗
53
Disable Download Callback
0
= callback required
1
= no callback required
Select whether a callback from the control panel is required for downloading.
Must be
0
for UL installations.
1
∗
∗
∗
∗
55
International Date Format
0
= disable (mm/dd/yy)
1
=
enable (dd/mm/yy)
Select the date format for display in the event log.
1
∗
∗
∗
∗
56
AC 60Hz/50Hz
0
= 60Hz
1
= 50Hz
Select the frequency for the AC.
Must be set to
0
for U.S. and Canadian installations.
1
∗
∗
∗
∗
57
Enable 5800 RF Button Global
Arm
0
= disable
1
= enable
If enabled, the system arms/disarms in accordance with the button’s user’s
global arming settings.
1
∗
∗
∗
∗
58
Enable 5800 RF Button Force
Arm
0
= disable
1
= enable
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE:
When attempting to arm the system, the keypad beeps once after the
button is pressed if any faulted zones are present.
ULC
Force Arming is not a ULC Listed feature and
must be disabled for ULC installations.
1
∗
∗
∗
∗
60
Zone 5 Audio Alarm Verification
0
= disable
1
= enable
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE:
Zone 5 cannot be used as protection zone.
1
∗
∗
∗
∗
70
Event Log Types
0
= disable
1
= enable
This field has five entries as follows: Alarm, Check, Bypass, Open/Close and
System. If enabled, the system logs those events into the event log.
1
∗
∗
∗
∗
71
12/24 Hour Type Stamp Format
0
= 12-hour
1
= 24-hour
Select the type of time stamping for the event log.
1
∗
∗
∗
∗
72
Event Log Printer On-Line Mode
0
= disable
1
= enable
If enabled, the system prints the events as they occur.
If disabled, the system prints the log only upon request.
1
∗
∗
∗
∗
74
Relay Timeout XXX Minutes
Enter
000-127
times 2 minutes (000-254).
This is used for #80 Menu Mode Time-Driven event relay command numbers
“04/09” and
Output Programming
in the
#93 Menu Mode Programming
output
command “56.”
1
∗
∗
∗
∗
75
Relay Timeout YYY Seconds
Enter
000-127
seconds.
This is used for #80 Menu Mode Time-Driven event relay command numbers
“05/10” and
Output Programming
in the
#93 Menu Mode Programming
command “57.”
Содержание VISTA-128BPT
Страница 2: ......
Страница 46: ......
Страница 56: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide 4 10 ...
Страница 88: ...V128BPT V250BPT Installation and Setup Guide 8 2 ...
Страница 104: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide C 2 ...
Страница 112: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Glossary 6 ...
Страница 118: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Index 6 ...
Страница 120: ...For the latest warranty information please go to www honeywell com security hsc resources wa ...
Страница 121: ...NOTES ...
Страница 122: ...NOTES ...
Страница 123: ...NOTES ...