Section 5 – Data Field Descriptions
5-3
FIELD
TITLE and DATA ENTRIES
EXPLANATION
∗
∗
∗
∗
22
Keypad Panic Enables (partition-
specific)
0
= disable
1
= enable
If enabled, the keypad panics (zones 995, 996, and 999) may be used in this
partition. There are three entries in this field, one for each panic.
∗
∗
∗
∗
23
Multiple Alarms (partition-
specific)
0
= disable
1
= enable
If enabled, allows more than one alarm sounding for a given zone during an
armed period.
NOTE:
that multiple alarm soundings will not occur more frequently than
allowed by the programmed alarm sounder duration. This has no impact on
the number of communication messages transmitted.
Must be 1 for UL installations.
∗
∗
∗
∗
24
Ignore Expansion Zone Tamper
0
= disable (tamper detection)
1
= enable (no tamper detection)
If disabled, the system monitors the tampers on expansion zones.
NOTE:
Only applicable to certain polling loop sensors with tamper switches or
5800 Series transmitters.
Must be
0
for UL installations.
∗
∗
∗
∗
26
Intelligent Test Report
0
= disable
1
= enable
If enabled, no test report is sent if any other type of report was sent since the
last test report.
If disabled, test reports are sent at the set intervals, regardless of whether or
not any other report has been sent.
Must be
0
for UL applications.
∗
∗
∗
∗
27
Test Report Interval
Enter
0001-9999
for the test report interval in
hours.
Enter
0000
for test reporting.
If a test report is desired, enter a test code in
Report Code Programming
in
#93 Menu Mode
. Set first test report time in field
∗
83.
Maximum Test report interval is 0024 for UL installations.
∗
∗
∗
∗
28
Power-Up in Previous State
0
= disable
1
= enable
If enabled, the system, upon power-up, reverts to its status prior to a complete
power loss.
If disabled, the system always powers up in a disarmed state.
NOTE:
Neither authority level 0 nor 5 can be used to disarm the system if the
control powers up armed.
Must be
1
for UL applications.
∗
∗
∗
∗
29
Quick Arm (partition-specific)
0
= disable
1
= enable
If enabled, allows arming of the burglary system in AWAY, STAY, INSTANT,
or MAXIMUM mode by using the [#] key instead of the user code.
NOTES:
When armed, the system reports closing as User 0 if Open/Close reporting for
User #2 (typically a Master level user) was enabled for a given partition.
If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot
disarm the system.
∗
∗
∗
∗
30
Phone Linecut Detect
0
= disable
1
= enable
Select phone linecut detection.
∗
∗
∗
∗
31
PABX Access Code
Enter
00-09; B-F (11-15)
This field is used to enter up to four 2-digit numbers representing the prefix
needed to obtain an outside telco line. If not required, enter nothing and
proceed to next field.
∗
∗
∗
∗
32
Primary Subscriber’s Account
Number (partition-specific)
Enter
00-09; B-F (11-15)
Enter a 4- or 10-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 4-digit account number is to be used, enter data
only in the first four locations, and enter * in the fifth location.
∗
∗
∗
∗
33
Primary Phone Number
Enter
0-9; #11
for
∗
, #12
for
#, #13
for
a 2-
second pause.
Enter the primary central station phone number, up to 17 digits. This is the
phone number the control will use to transmit Alarm and status messages to
the central station. Do not fill unused spaces.
NOTE:
Backup reporting is automatic only if a secondary phone number is
entered.
Содержание VISTA-128BPT
Страница 2: ......
Страница 46: ......
Страница 56: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide 4 10 ...
Страница 88: ...V128BPT V250BPT Installation and Setup Guide 8 2 ...
Страница 104: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide C 2 ...
Страница 112: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Glossary 6 ...
Страница 118: ...VISTA 128BPT VISTA 250BPT Installation and Setup Guide Index 6 ...
Страница 120: ...For the latest warranty information please go to www honeywell com security hsc resources wa ...
Страница 121: ...NOTES ...
Страница 122: ...NOTES ...
Страница 123: ...NOTES ...